Extron electronic MSX1616HR operation manual Menu Programming, Level Selection, Or Out

Models: MSX1616HR MSX1616

1 40
Download 40 pages 25.92 Kb
Page 21
Image 21

19

Menu Programming

Level Selection

The MSX1616 has six user-definable switching levels:

Level Number:

Default Level:

1

2

3

4

5

6

RGBHVA

RGBHV

Audio

No boards

No boards

No boards

Each level can be one of nine board configurations:

RGBHVA

Red

RGBHV

Green

RGB

Blue

SYNC

No boards

Audio

In or Out

Use this function to create a patch using the LCD menu functions:

1.Press MENU button until &XUUHQW￿/HYHO displays in the LCD.

2.Press the soft key pointing to ,Q or 2XW on the LCD.

Result: The LCD shows ,QSXW￿￿ and 2XWSXW￿￿, or the last output or input number designated.

3.Press the left and right arrow buttons to move forward or backward to the desired input.

4.Use the up and down arrow buttons to move between the ,Q and 2XW fields.

5.Press the left and right arrow buttons to move forward or backward to the desired output number.

6.Press ENTER to accept the patch.

Note: When using the LCD menu, patches are limited to one input and one output.

 2002 - INLINE, INC.

MSX1616 OPERATION MANUAL - v1.0 5/8/02

Page 21
Image 21
Extron electronic MSX1616HR operation manual Menu Programming, Level Selection, Or Out