Switching Commands

These commands can either initiate a one-input-to-one-output switch or load an entire I/O configuration. You must fallow all "load" commands (identified by [L….]) by a [TAKE]

command to initiate switch.

COMMAND

[MSxOooIii]

[MSxOoo?] [MSx?]

[LMS,x,aa,bb,cc,dd,ee,ff,gg,h

h,ii,jj,kk,ll,mm,nn,oo,pp]

[LMS,l?]

[LMS,?]

[TAKE]

DESCRIPTION

Executes a matrix switch of an input to an output for a specific level.

Where

ox = 1 - 6 for specific level o oo = 01 – 16 for output

o ii = 00 – 16 for input (00 = blank)

Example:

Desired Action:

oOn Level 1, Patch Output 13 to Input 8

Required Code:

o[MS1O13I08]

Returns the current connections for Level x

Preloads an I/O configuration for a specific level. Each output has a two-character placeholder for an input assignment to that output. Inserting 00 will blank the output.A [TAKE] command must be sent to execute switches.

Where

ox = 1 - 6 for specific level

oaa = 00 – 16 designating an input to assign

to output 1

obb = 00 – 16 designating an input to assign

to output 2

occ = 00 – 16 designating an input to assign

to output 3

odd = 00 – 16 designating an input to assign to output 4

oee = 00 – 16 designating an input to assign to output 5

off = 00 – 16 designating an input to assign to output 6

ogg = 00 – 16 designating an input to assign

to output 7

ohh = 00 – 16 designating an input to assign

to output 8

oetc.

Query pre-loaded configuration

l = 1 – 6 for specific level Queries all levels.

Causes previously loaded parameters to take effect.

 2002 - INLINE, INC.