Extron electronic MSX1616HR operation manual Voll?, Volr?, Volstop

Models: MSX1616HR MSX1616

1 40
Download 40 pages 25.92 Kb
Page 33
Image 33

COMMAND

[VOLLoox]

[VOLL?]

[VOLLooxxx]

[VOLRoox]

[VOLR?]

[VOLRooxxx]

[VOLRMPoox]

[VOLSTOP]

[VIN@]

[VIN+/-]

[VIN?]

31

DESCRIPTION

Increments/decrements left channel volume level for a specific output.

Where

ooo = 01 – 16 for output

ox = + (plus sign) to increment output volume

ox = - (minus sign) to decrement output volume

ox = @ to return output volume to factory default (0 dB)

ox = ? to request current volume level Queries all left volumes.

Sets left channel volume level for a specific output.

Where

ooo = 01 – 16 for output

oxxx = -550 to 90

Note: Level is set in .5 dB steps . For example, –23.5 dB is entered as -235

Increments/decrements right channel volume level for a specific output.

Where

ooo = 01 – 16 for output

ox = + (plus sign) to increment output volume

ox = - (minus sign) to decrement output

volume

ox = @ to return output volume to factory

default (0 dB)

ox =? to request current volume level Queries all right volumes.

Sets right channel volume level for a specific output.

Where

ooo = 01 – 16 for output

oxxx = -550 to 90

Note: Level is set in .5 dB steps, for example, –23.5 dB is entered as -235

Starts volume ramp of a specific output. Volume gradually increases/decreases

Where

ooo = 01 – 16 for output

ox = + (plus sign) for volume ramp up

ox = - (minus sign) for volume ramp down Stop volume ramp function.

Restores Factory Default for all Input volume levels (0 dB)

Increments/decrements all input volume levels. Queries all input volume levels.

 2002 - INLINE, INC.

MSX1616 OPERATION MANUAL - v1.0 5/8/02

Page 33
Image 33
Extron electronic MSX1616HR operation manual Voll?, Volr?, Volstop