COMMAND

[PCLpPmmmabcde] [PCLpPmmm?]

[PCCpIii]

[PCCpOoo]

[PCCpPmmm]

[PCPDpxx]

[PRST]

35

DESCRIPTION

Loads ASCII command string to a preset up to 60 characters.

Where

op = 2 for port 2, 3 for port 3 o mmm = 001 - 256 for preset

o abcdef… = hex string to be stored o abcdef - ?, queries current label

Note: When controlling Inline products that also use brackets as delimiters, replace open bracket [with ‘ and closed bracket] with " in the abcde… portion of the command. When this command is sent out the command port the ‘ " will automatically be replaced with [ ].

Forces command string loaded to a specific input to be sent.

Where

op = 2 for port 2, 3 for port 3 o ii = 01 – 16 for input

Forces command string loaded to a specific output to be sent.

Where

op = 2 for port 2, 3 for port 3 o oo = 01 – 16 for output

Forces command string loaded to a specific preset to be sent.

Where

op = 2 for port 2, 3 for port 3 o mmm = 001 – 256 for preset

Sets projector code delay to a defined period.

Where

op = 2 for port 2, 3 for port 3 o x = 0 for a 0 second delay o x = 1 for a 1 msec. delay o x = 2 for a 5 msec. delay o x = 3 for a 10 msec. delay o x = 4 for a 20 msec. delay o x = 5 for a 50 msec. delay

o x = 6 for a 100 msec. delay, x = ? to query

Resets all projector command codes to null.

Preset Commands

The MSX1616 has the ability to store and recall common configurations. Both units offer 256 presets available via serial control. The MSX3216 has 48 presets available via the front panel, while the MSX1616 has 32 presets available via the front panel.

COMMAND

[PSVxxx]

[PRCxxx]

DESCRIPTION

Save current configuration to preset memory.

Where

oxxx = 001 – 256

Recall stores configuration from preset memory.

Where

oxxx = 001 – 256

 2002 - INLINE, INC.

MSX1616 OPERATION MANUAL - v1.0 5/8/02

Page 37
Image 37
Extron electronic MSX1616HR operation manual Preset Commands, PCCpIii PCCpOoo PCCpPmmm PCPDpxx, Prst, PSVxxx PRCxxx