COMMAND

[RGBxx]

[VISx]

DESCRIPTION

RGB delay provides an adjustable delay time between switching sync and RGB boards.

Where

ox.x = 0.0 – 6.0 in .1 seconds intervals, ? to query Enable/Disable Vertical Interval Switching. Requires sources to be Genlocked. Contact Inline Inc. For specific application support.

Where x = 0 to disable, 1 to enable, ? to query

Level Commands

Level commands are a command subset that involves the assigning of boards into switching levels. Levels can consist of combinations of R, G, B, HV and audio boards. You can access six assignable levels via the front panel or serial control. For commands that use level designators, see Switching Commands and Volume Commands.

Default Levels include:

Level 1 - RGBHVA

Level 2 - RGBHV

Level 3 - Audio

Level 4-6 - No Boards

COMMAND

[LVLx]

[LVL??]

[LVLxyyy]

DEFINITION

Sets current working level of switcher.

Where

ox = 1 - 6, x = ? query Queries all levels.

Assigns individual boards to a specific level.

Where

ox = 1 - 6

oyyy = RGBHVA for all boards o yyy = RGBHV for RGB and sync o yyy = RGB for RGB only

o yyy = SYNC for sync only o yyy = AUD for audio only o yyy = RONLY for red only o yyy = GONLY for green only o yyy = BONLY for blue only o yyy = NO for no boards