Ericsson LBI-39224 manual Logging Recorder Configuration Dialog Box

Models: LBI-39224

1 330
Download 330 pages 24.07 Kb
Page 204
Image 204

LBI-39224

(No), or cancel the Close command (Cancel) and remain in the DC Controlled Station State Table Mapping dialog box.

3.15 LOGGING RECORDER CONFIGURATION

The Logging Recorder Interface Module (LRIM) interface is used to record audio for selected units, groups and conventional channels. The CEC/IMC supports four (4) LRIM devices, each device supporting up to 64 modules and 32 channels. Each module assigns a unit, group, or conventional channel to a specific LRIM channel.

Logging Recorder configuration is performed from the

Logging Recorder Configuration dialog box. From the CEC/IMC

Manager

menu

bar

 

select

Configure System

/

CEC/IMC Configuration

/

LRIM

to

display

the

Logging Recorder Configuration dialog box, Figure 38.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 38 Logging Recorder Configuration Dialog Box

Help

Choose the Help button to access the Help function. (Help is also available by pressing the F1 key.)

The current Logging Recorder is displayed in the drop-down list box at the top center of the Logging Recorder Configuration dialog box. Select the desired Logging Recorder to view or configure from this list box (LRIM 1 - 4).

The Module List list box contains all of the programmable (configurable) modules for the selected Logging Recorder. The module number, entity alias, channel number, and output level (volume) are

3-174

Page 204
Image 204
Ericsson LBI-39224 manual Logging Recorder Configuration Dialog Box