LBI-39224

COM 1, COM 2, COM 3 or COM 4, as required using the respective option button in the dialog box.

The selected serial port interrupt request line (IRQ) and base I/O port address settings are established from the Microsoft Windows NT Control Panel program settings. Typically, no IRQ or address changes are ever required. However, if using non-standard serial port hardware, changes may be necessary. If using non-standard serial port hardware, consult the hardware manufacture's documentation for specific IRQ and base I/O address details.

CEC/IMC Manager-MOM Baud Rate

Baud rate selection for the CEC/IMC Manager MOM Controller Board serial link is accomplished using the CEC/IMC Manager BAUD Rate drop-down list box. In this list box baud rates of 9600 and 19.2k baud are available, select 9600 or 19.2k baud as required. This setting configures the previously chosen PC COM port for the selected rate. Since the MOM Controller Board port used for CEC/IMC Manager interfacing is auto-baud sensing, a baud rate change at the MOM Controller Board is not necessary when a change is made in this list box.

System Manager-MOM Baud Rate

The MOM Controller Board port used for interfacing with the System Manager computer is configurable for 9600 or 19.2k baud using the System Manager BAUD Rate drop-down list box. Unlike the CEC/IMC Manager MOM Controller Board setting, this setting must match the setting at the System Manager before MOM Controller Board System Manager communication can occur, the System Manager is not equipped with an auto-baud serial port. Refer to your particular System Manager LBI for System Manager baud rate configuration information. Select 9600 or 19.2k baud as required from the drop-down list box.

Data Logging Of GSC Traffic

Once each day at midnight (00:00), the CEC/IMC Manager creates a new datalog file and it names the file in accordance with the date. For example, a datalog file created on July 2, 1996 will be named 07_02_96.DLG. This data can be viewed using the on-line Calls Translation and GSC Monitor functions (available by selecting Monitor System on the CEC/IMC Manager menu bar) described in Chapter 4, SYSTEM MONITORING, or the CALLS.EXE and

3-11

Page 41
Image 41
Ericsson LBI-39224 manual CEC/IMC Manager-MOM Baud Rate, System Manager-MOM Baud Rate, Data Logging Of GSC Traffic