Safety Warnings

HIGH PRESSURE SPRAY CAN CAUSE EXTREMELY SERIOUS INJURY. OBSERVE ALL WARNINGS.

INJECTION HAZARD

Fluids under high pressure from spray or leaks can penetrate the skin and cause extremely serious injury, including the need for amputation.

NEVER point the spray gun at anyone or any part of the body.

NEVER put hands or fingers over the spray tip. Do not use a rag or any other material over your fingers. Paint will penetrate through material and into the hand.

NEVER try to stop or deflect leaks with your hand or body.

NEVER try to "blow back" paint, this is not an air spray sprayer.

ALWAYS have gun tip guard in place when spraying.

ALWAYS lock gun trigger when you stop spraying.

ALWAYS remove tip from the gun to clean it.

ALWAYS follow the PRESSURE RELIEF PROCEDURE, as shown on page 10, before cleaning or removing the spray tip or servicing any system equipment.

ALWAYS Be sure equipment safety devices are operating properly before each use.

ALWAYS tighten all fluid connections before each use.

MEDICAL TREATMENT

If any fluid appears to penetrate your skin, get EMERGENCY CARE AT ONCE. DO NOT TREAT AS A SIMPLE CUT.

*Go to an emergency room immediately.

*Tell the doctor you suspect an injection injury.

*Tell him what kind of material you were spraying with and have him read NOTE TO PHYSICIAN.

MEDICAL ALERT - Airless Spray Wounds

NOTE TO PHYSICIAN:

If any fluid appears to penetrate your skin, get

EMERGENCY MEDICAL CARE AT ONCE. DO NOT TREAT AS A SIMPLE CUT. Tell the doctor exactly what fluid was injected. Have him read the following "NOTE TO PHYSICIAN".

Injection in the skin is a traumatic injury. It is important to treat the injury surgically

as soon as possible. DO NOT DELAY treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the bloodstream. Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable.

GENERAL PRECAUTIONS

 

 

• NEVER alter equipment in any manner.

• NEVER smoke while in spraying area.

• NEVER spray highly flammable materials.

• NEVER use around children.

NEVER allow another person to use sprayer unless they are thoroughly instructed on safety use and given this operators manual to read.

ALWAYS wear a spray mask, gloves and protective eye wear while spraying.

ALWAYS ensure fire extinquishing equipment is readily available and properly maintained.

NEVER LEAVE SPRAYER UNATTENDED WITH PRESSURE IN THE SYSTEM. FOLLOW PRESSURE RELIEF PROCEDURES ON PAGE 10.

3

Image 5
Contents SERVICE/OPERATION Table of Contents Introduction IntroductionToxic Fluid Hazard Safety WarningsMedical Treatment Always ground all of these components Flushing When Testing for Spark Before Performing Adjustments or RepairsFlushing Airlessco Throat Seal Oil Ounce bottle Quart bottle Daily MaintenanceUSE Minimum Pressure Pressure Relief ProcedureConnect the hose and gun Setting Up to Stripe or SprayRemove the snap-on cover plate over the piston Grounding Flush the sprayerStarting Up Adjusting the PressurePrepare the Material Starting the SprayerAvoiding Tip Clogs When Shutting off the SprayerRefer to figure below Striping OperationSpray Gun Operation Spray TIP AssemblySpray GUN Major Components of Spray GUN Reversible REV-TIPTest the Pattern Correction Spray Gun TroubleshootingDefects Cause Problem Cause Solution Field TroubleshootingFluid Pump Disconnect Servicing the Fluid PumpServicing the Piston Rod Outlet Valve Servicing the Suction AssemblyReplacement Instructions Packing Replacement ProceduresPacking Replacement Procedures Pressure Calibration on the Electrical Control Board Electrical Control Board ReplacementRemove Clutch AS Follows Clutch ReplacementInstall NEW Clutch AS Follows Troubleshooting Clutch Does Not Engage Part Number Description Gear Box Assembly Part NoGun Mount Assembly Part No Spray Gun Assembly Part NoFrame Assembly Part Number Description Qty Swivel Wheel Assembly Suction Assembly Part NoOrifice Size Inches Striping Tip GuideStriping TIP Accessoriesairlessco Quick F