Servicing the Fluid Pump
Fluid Pump Disconnect | Fluid Pump Reinstall |
Refer to Figure 1
1.Follow the Pressure Relief Procedure on page 10.
2.Flush the material you are spraying out of the machine.
3.Remove the connecting rod shield
4.Move the piston rod
5.Remove the retaining ring
6.Remove the suction tube assembly from the fluid pump
7.Using a 1/2” wrench unscrew the two bolts
8.Remove the connecting rod pin
FIGURE 1
Refer to Figure 1 & 4
1.Loosen the packing nut and ensure that the piston rod
2.Push the piston rod up into the connecting rod (331-
038)& align the holes. Insert the connecting rod pin
3.Push the two bolts
234).Using a 1/2” wrench, tighten the two bolts evenly (alternating between them) until you reach 20
4.Reassemble lower suction valve assembly by placing the suction seat
5. Start the machine and operate slowly to check the piston rod for binding. Adjust the two bolts, holding the fluid pump body to the cover assembly, if necessary. This will eliminate any binding.
6.Tighten the packing nut clockwise until resistance is felt against the Belleville Springs, then go 3/4 of a turn more. Put five drops of Airlessco Throat Seal Oil into the packing nut.
7.Run the machine at full pressure for several minutes. Release the pressure by following the Pressure Relief Procedure & readjust the packing nut per step 6 above.
8.Install the connecting rod shield
17