PRE-INSTALLAT!ON REQUIREMENTS

Tools Required for Installation:

I.Phillips screwdriver

2.10 mm socketwith ratchet.

3.Channel-lock adjustable pliers.

4.Carpenter's level.

ELECTRICAL REQUIREMENTS

CIRCUIT- Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker.

POWER SUPPLY- 2 wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current. NOTE: Because of potential inconsistent voltage capabilities, the use of this washer with power created by gas powered generators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended.

OUTLET RECEPTACLE - Properly grounded 3-prong receptacle to be located so the power supply cord is

accessible when the washer is in an installed position. NOTE: GFI (Ground Fault Interrupter) receptacle is not required.

GROUNDING REQUIREMENTS

Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt asto whether the appliance isproperly grounded.

. The washer MUST be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by a path of least resistance for electrical current.

. Since your washer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUSTbe plugged into an appropriate, copper wired receptacle that is properly installed and grounded in accordance with all local codes and ordinances or in the

absence of local codes, with the National Electrical Codes, ANSI/NFPA 70 (latest edition). If in doubt, call a licensed electrician. DO NOTcut off or alter the grounding prong on the power supply cord. In situations where a two-slot receptacle is present, it is the owner's responsibility to have a licensed electrician replace it with a properly grounded three prong grounding type receptacle.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within 42 inches (107 cm) of your washer'swater inlet. The faucets MUST be 3/4 inch (1.9 cm) garden hose type so inlet hoses can be connected. Water pressure MUST be between 30 and 120 pounds per squareinch (maximum unbalance pressure, hot vs. cold, 10 psi.) Your water department can advise you of your water pressure.

DRAIN REQUIREMENTS

I.Drain capable of eliminating 17 gals (64.3 L) per minute.

2.A standpipe diameter of I-I/4 in. (3.18 cm) minimum.

3.The standpipe height above the floor should be: Minimum height: 24 in. (61 cm)

Maximum height: 96 in. (244cm)

r

 

 

96

in.

 

 

(244

cm)

o

OO

Max.

T

24 in.

(61 cm) Min.

BACKl

I I

NOTE:

Drain hose attached to the washer can reach a 79 in. (201 cm) high standpipe. For higher standpipe, use hose P/N 134889610, available from an authorized parts distributor.

Image 2
Contents Full Size Tumble Action Washers Grounding Requirements PRE-INSTALLAT!ON RequirementsElectrical Requirements Water Supply RequirementsROUGH-INDIMENSIONS InchescmLocation of Your Washer Do not Install Your WasherMinimum Installation Clearances UnpackingZeve/ing the Washer Metal P clampHose clips Washer ConnectionsReplacement Parts Cable Tie