3.Pull console forward then tilt it back.
4.Remove washer cabinet clip on right side under console. Use screwdriver blade as shown.
NOTE: For additional security, top can be locked to washer with a lock and key in the hole provided. Screw type lock available from industry sources.
NOTE: Place all screws and other items removed from coin slide assembly on a cloth so they will not get lost.
2
I
!.Clips
2. Clip
3. Screwdriver Blade
5.Open top access panel in meter case. Loosen timer bolts with Phillips screwdriver and lift timer out of the way. NOTE: You do not have to disconnect the timer.
!.Access Panel
2. Clip
6.Remove washer cabinet clip inside meter case, using screwdriver.
7.Pull cabinet up and forward to remove.
Replacing Cabinet
1.Put cabinet in place on washer.
2, Replace clips at top rear of washer cabinet.
3, Put timer back in place in meter case and tighten timer bolts. 4, Replace meter case access panel.
5, Swing console down into place, push toward rear. 6, Replace 2 console screws,
7, Plug in washer or reconnect power.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Unplug washer or disconnect power.
2.Remove slide mechanism from meter case.
3.Remove slide return spring.
4.Place coin(s) in coin slot(s) and push forward all the way.
5.Remove buffer.
6.Turn coin chute upside down and install or remove required number of
7.Reassemble buffer.
8.Pull slide back to original position and reassemble slide return spring.
10