| ERROR CODES |
|
|
|
DISPLAY |
| EXPLANATION AND RECOMMENDED PROCEDURE |
F/11 | Serial Communication Error | |
| Communication between the Central Control Unit (CCU) and the Motor Control Unit | |
| (MCU) cannot be sent correctly. | |
| Potential Causes | |
| • Check Wire Harness connections to the MCU, the motor, and Central Control | |
|
| Unit (CCU) |
| • Check the Drive system for any worn or failed components | |
| • | Check MCU |
| • | Check CCU |
| • | Check Motor |
| • | Check Wire Harness |
|
| |
F/13 | Dispenser Circuit Error | |
| If the dispenser motor is not able to be driven to it’s proper position. | |
| Potential Causes | |
| • Check mechanical linkage from dispenser motor to the top of the dispenser. | |
| • Check Wire Harness connections to the dispenser motor and Central Control | |
|
| Unit (CCU) |
| • | Check Dispenser Motor |
|
| |
F/14 | EEPROM Error | |
| The Central Control Unit (CCU) receives it’s data from an EEPROM onboard the | |
| CCU. If there is an error reading this data it will cause this error. | |
| Potential Causes | |
| • A power glitch may cause this error. Try unplugging the Unit for two minutes to | |
|
| see if that fixes the error. |
| • | Check CCU. |
|
| |
F/15 | Motor Control Unit (MCU) Error | |
| If the MCU detects multiple resets or errors during a wash cycle it will go into this | |
| error mode. | |
| Potential Causes | |
| • Check Wire Harness connections to the MCU, the motor, and Central Control | |
|
| Unit (CCU) |
| • | Check Drive belt |
| • | Check MCU |
| • | Check Motor |
| • | Check Wire Harness |
|
| |
Sud | SUDS LOCK (Overdose of Detergent detected during the Wash Cycle) | |
| The motor control unit senses a suds lock condition by analyzing the current draw on | |
| the drive motor. If “Sud” is displayed a potential suds lock is detected. This may | |
| signify a bad pump, an extra heavy load, excessive detergent, or excessive suds. | |
|
|
|
6 - 6