Motor Continuity Test
Disconnect the wire harness from the motor and measure the resistance of the motor windings.
Motor Connector | Results |
Pin 1 to Pin 2 | Normal = approximately 6 Ω |
| Abnormal = infinity |
|
|
Pin 2 to Pin 3 | Normal = approximately 6 Ω |
| Abnormal = infinity |
|
|
Pin 1 to Pin 3 | Normal = approximately 6 Ω |
| Abnormal = infinity |
|
|
Water Temperature Sensor
Disconnect the wire harness from the water temperature sensor and measure the resistance of the sensor.
Temperature | Results |
32° F (0° C) | 35.9K Ω |
86° F (30° C) | 9.7K Ω |
104° F (40° C) | 6.6K Ω |
122° F (50° C) | 4.6K Ω |
140° F (60° C) | 3.2K Ω |
158° F (70° C) | 2.3K Ω |
203° F (95° C) | 1K Ω |
|
|
6 - 9