PROBLEM | POSSIBLE CAUSE/TEST | |
| Note: Possible Cause/Tests MUST be performed in the sequence | |
| shown for each problem. | |
|
|
|
OVER FILLS | 1. | Verify the unit is level. |
| 2. | Check pump drain system – this could indicate a failure to drain. |
| 3. | Check Operating Pressure Switch. |
| 4. | Check Pressure Switch hose. |
| 5. | Check Flow Meter operation. |
| 6. | Check the CCU. |
|
|
|
BASKET WON’T ROTATE | 1. | Check Drive belt. |
| 2. | Check Drive motor. |
| 3. | Check Wire Harness connections. |
| 4. | Check Motor Control Unit. |
|
|
|
MOTOR OVERHEATS | 1. | Check Drive motor. |
| 2. | Check Wire Harness connections. |
| 3. | Check Drive belt. |
| 4. | Check Motor Control Unit. |
|
|
|
WON’T DRAIN | 1. | Check Wire Harness connections. |
| 2. | Check Drain pump. |
| 3. | Check Drain pump motor. |
| 4. | Check that the Drain hose and Drain Pump Filter is clear of |
|
| foreign objects. |
| 5. | Check the CCU. |
|
|
|
MACHINE VIBRATES | 1. | Remove Shipping system. |
| 2. | Check installation. |
| 3. | Check leveling feet. |
| 4. | Check leveling feet lock nuts. |
| 5. | Check for weak floor. |
|
|
|
INCORRECT WATER | 1. | Check that the Inlet Hoses are connected properly. |
TEMPERATURE | 2. | Check the Water Heater and Wire Harness connections to it. |
| 3. | Check Water Temperature Sensor for an abnormal condition. |
| 4. | Check the CCU. |
|
|
|