5.L.E.D DISPLAY INDICATOR NUMBER 5

a.Air Jet Circuit - OPTIONAL

1.This indicator dot is on at the end of the dryer cycle for approximately 60 seconds.

C.PHASE 6 OPL MICROPROCESSOR CONTROLLER RELAY OUTPUT L.E.D. INDICATORS

There are a series of five (5) L.E.D. indicators (ORANGE LIGHTS) located at the backside are of the Phase 6 OPL microprocessor controller (computer). These are identified or labeled (from top to bottom in the illustration below as: FAN-BLOWER, FOR-FORWARD, REV-REVERSE, AIR-AIR-JET, HT1-HEAT OUTPUT. There are a series of seven (7) L.E.D. indicators (red lights) FUSE-MAIN FUSE, LINT-LINT DOOR, MAIN-MAIN DOOR, DRUM-TUMBLER HI-LIMIT, SAIL-SAIL SWITCH, BURN-BURNER HI LIMIT, FLAME-FLAME PROBE). The L.E.D. in the center of the board (red light) indicates power supplied to the Phase 6 OPL microprocessor controller (computer). These L.E.D.'s indicate the inputs and outputs of the Phase 6 OPL microprocessor (computer) as it monitors the safety circuits.

44

Image 48
Contents AD-95/ML-95 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Troubleshooting Safety Precautions SectionCleaning WeeklyDays MonthsAdjustments Seven Days after Installation and every 6 MonthsLubrication Enclosure, Air Supply, and Exhaust Requirements Electrical and Gas RequirementsOperational Service Check Procedure Prior to February 11 Control Panel Microprocessor As of February 11With circuit breaker Reversing Relay Panel With fusesGas Burner Assembly HSI Module Gas ModelsDrive Motor Blower Motor and ImpellerTaperlock Trantorque Drive Shaft Assembly Idler Shaft Assembly Transtorque TaperlockMain Door Switch Basket TumblerSail Switch Gas Models Only Hi-Limit Gas Models OnlyAutomatic Reset Thermostat Lint ScreenLint Drawer Switch Servicing Computer ControlsTo Replace Keyboard Label Assembly Ignition Controls To Remove Flame Sensor ProbeHSI Ignitor Flame Sensor Probe To Test and Adjust Gas Water Column Pressure To Replace Gas Valve See burner illustration onTo Replace Main Burner Orifices To Convert Natural Gas to L.P. Gas To Replace Burner TubesDiscontinue power to the dryer To Replace HSI ModuleSail Switch Assembly Gas Models Only To Replace Sail SwitchTo Adjust Sail Switch To Replace Main Door Switch To Replace Main Door AssemblyTo Install New Main Door Glass as of October 24 Front Panel and Main Door AssembliesAs of October 24 Prior to October 24 To Install new Main Door Glass prior of October 24 To Replace Front PanelTo Replace Main Door Hinge Block Pulleys To Replace Drive Shaft Pulley To Replace Drive Motor PulleyPage Tumbler Wheel Replacement on IdlerAssembly taper lock models Tumbler Wheel Replacement on IdlerAssembly trantorque models To Replace Blower Shaft PulleyBasket Assembly To Replace Blower Motor PulleyTo Replace Drive Assembly Pillow Block Bearing Belt Adjustment Motor to Drive AxleTo Replace Idler Shaft Pillow Block Bearing To Replace Drive Motor V-Belts MotorsTo Replace Impeller Motor Fan Shaft Drive To Replace Blower Motor V-belts To Replace Front Thruster WheelsRear Access ImpellerLint Screen Assembly To Replace Lint Door SwitchTo Replace Lint Screen No display on computer Computer will not accept key pad entriesDryer will not start, but computer display indictors are on Drive motor runs, burner is on, but basket will not turnBurner hi-limit safety thermostat is tripping Thermal overload for drive motor is trippingOverload for impeller fan motor is tripping There is excessive vibration coming from the basket Phase 6 OPL System Diagnostics Page E.D. Display Indicators E.D Display Indicator Number AIR AIR JET Output L.E.D. Indicator Optional FAN Blower Output L.E.D. IndicatorFuse Main Fuse Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. Indicator E.D. Codes BURNER Safety Fail DRUM Safety FailBURNER Control Fail BURNER Flame FailComputer Logic and Wiring Diagram No Display Condition Drive motor reverses but does not forward, blower motor runs Blower motor does not operate, drive motor runsLint Door Condition Main Door ConditionMicroprocessor Which Must be Reset Manually Technical Information For exampleData Label HOW to USE a Manometer AD-95/ML-95 Tool List ADC450188 1- 01/14/99-25