7.bURNER FLAME FAIL- This routine allows two (2) Flame out retries to occur before proceeding into the error. The count of two (2) will be established every time the call for heat was to occur. Only if it reaches the count of two (2) before the tumbler temperature has reached the set temperature will this error be triggered. The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F. If the tumbler temperature is below 100º F upon failure, the machine will shut down and display "bURNER FLAME FAIL" with an audio indication. This process will occur every time the heat output is active.

8.MAIN DOOR- This monitors the door circuit. If the machine was not active and the main door was opened the display would read "REAdY." If a program attempt was made with the main doors open the display will read "MAIN dOOR" with an audio indication. If the machine is active and the main door was opened the display would read "MAIN dOOR" with no audio indication and the dryer will shut down. Once the main door has closed the display would read "PRESS START" press the "ENTER/START" key and it will continue the programmed cycle.

9.LINT dOOR- This monitors the lint drawer and door circuit. If the machine was not active and the lint drawer and door was opened the display would read "REAdY." If a program attempt was made with the lint drawer and door open the display would read "LINT dOOR" with an audio indication. If the machine is active and the lint drawer and door was opened the display would read "LINT dOOR" with no audio indication and the dryer will shut down. Once the lint door was closed the display would read "PRESS START" press the "ENTER/START" key and it will continue the programmed cycle.

10.TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE- This routine monitors the tumbler temperature. When the temperature sensor or fuse opens with the machine not active the display will read "TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" with an audio indication. If the machine was active at the time that the temperature sensor or fuse opened the display would read 'TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE." If the tumbler temperature is above 100º F the machine will continue to display "TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" with an audio indication and run with no heat for three (3) minutes or until the temperature drops below 100º F. If the tumbler temperature is below 100º F upon failure the machine will shut down and display "TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" with an audio indica- tion. The display will continue to read "TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" an audio indication will sound for approximately 5 seconds, every 30 seconds until the problem is cor- rected or the power to the dryer is disconnected (and the problem is corrected).

NOTE: Once the Phase 6 microprocessor controller (computer) detects a problem in the heat circuit, it updates every 30 seconds, so that if the problem was a loose connection in the circuit which corrected itself, the "TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE" condition would automatically be cancelled and the display will return to "REAdY."

11.ROTATE SENSOR FAIL- Indicates a rotational sensor circuit failure meaning that there is a fault somewhere in the basket (tumbler) rotating circuit, or the Phase 6 OPL microprocessor controller (computer) program related to this circuit (program location 2) is set incorrectly. In the active mode it should be (ROTATE SENSOR ACTIVE), if the dryer is not equipped with the optional rotational sensor it should be set in the nonactive mode (No ROTATE SENSOR).

42

Image 46
Contents AD-95/ML-95 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Troubleshooting Safety Precautions SectionDays CleaningWeekly MonthsSeven Days after Installation and every 6 Months AdjustmentsLubrication Enclosure, Air Supply, and Exhaust Requirements Electrical and Gas RequirementsOperational Service Check Procedure Prior to February 11 Control Panel Microprocessor As of February 11With circuit breaker Reversing Relay Panel With fusesGas Burner Assembly HSI Module Gas ModelsDrive Motor Blower Motor and ImpellerTaperlock Trantorque Drive Shaft Assembly Idler Shaft Assembly Transtorque TaperlockMain Door Switch Basket TumblerSail Switch Gas Models Only Hi-Limit Gas Models OnlyAutomatic Reset Thermostat Lint ScreenLint Drawer Switch Servicing Computer ControlsTo Replace Keyboard Label Assembly To Remove Flame Sensor Probe Ignition ControlsHSI Ignitor Flame Sensor Probe To Replace Gas Valve See burner illustration on To Test and Adjust Gas Water Column PressureTo Replace Main Burner Orifices To Convert Natural Gas to L.P. Gas To Replace Burner TubesDiscontinue power to the dryer To Replace HSI ModuleTo Replace Sail Switch Sail Switch Assembly Gas Models OnlyTo Adjust Sail Switch To Install New Main Door Glass as of October 24 To Replace Main Door SwitchTo Replace Main Door Assembly Front Panel and Main Door AssembliesAs of October 24 Prior to October 24 To Replace Front Panel To Install new Main Door Glass prior of October 24To Replace Main Door Hinge Block Pulleys To Replace Drive Shaft Pulley To Replace Drive Motor PulleyPage Tumbler Wheel Replacement on IdlerAssembly taper lock models Tumbler Wheel Replacement on IdlerAssembly trantorque models To Replace Blower Shaft PulleyBasket Assembly To Replace Blower Motor PulleyBelt Adjustment Motor to Drive Axle To Replace Drive Assembly Pillow Block BearingTo Replace Idler Shaft Pillow Block Bearing Motors To Replace Drive Motor V-BeltsTo Replace Impeller Motor Fan Shaft Drive To Replace Blower Motor V-belts To Replace Front Thruster WheelsRear Access ImpellerTo Replace Lint Door Switch Lint Screen AssemblyTo Replace Lint Screen Dryer will not start, but computer display indictors are on No display on computerComputer will not accept key pad entries Drive motor runs, burner is on, but basket will not turn Thermal overload for drive motor is tripping Burner hi-limit safety thermostat is tripping Overload for impeller fan motor is tripping There is excessive vibration coming from the basket Phase 6 OPL System Diagnostics Page E.D. Display Indicators E.D Display Indicator Number AIR AIR JET Output L.E.D. Indicator Optional FAN Blower Output L.E.D. IndicatorFuse Main Fuse Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. Indicator E.D. Codes BURNER Control Fail BURNER Safety FailDRUM Safety Fail BURNER Flame FailComputer Logic and Wiring Diagram No Display Condition Drive motor reverses but does not forward, blower motor runs Blower motor does not operate, drive motor runsLint Door Condition Main Door ConditionMicroprocessor Which Must be Reset Manually Technical Information For exampleData Label HOW to USE a Manometer AD-95/ML-95 Tool List ADC450188 1- 01/14/99-25