American Dryer Corp AD-95 service manual E.D. Codes

Page 52

C. L.E.D. CODES

1.Display Codes

A

ALL REV

ANTI WRINKL dELAY TIME ANTI WRINKL GUARd ACTIVE ANTI WRINKL GUARd ON TIME AUTO CYCLE

b

bURNER CONTROL FAIL bURNER FLAME FAIL bURNER SAFETY FAIL bUZZ

bUZZ TIME CEL

CHECK MAIN FUSE CLEAN LINT COOL

COOL TIME_M

COOL TEMP_ CYCLEA CYCLEb

CYCLEC

CYCLED

CYCLEE

CYCLEF dONE dRYING dRY LEVEL_ dRY TEMP F_ dRY TIME_M

dRUM SAFETY FAIL ELAPSE TIME_MIN ELECTRIC

F FAR FLASH GAS HOT LINT dOOR

LINT COUNT

_M REMAIN MAIN dOOR

MANUAL CYCLE

MAX ANTI WINKL GUARd

NFLASH NoAIR FLOW

NoANTI WRINKL GUARd NoBUZZ

NoHEAT

NoREV

No ROTATE SENSOR PROGRAM REAdY

ROTATE SENSOR ACTIVE ROTATE SENSOR FAIL _RPM

SAIL SWITCH FAIL

SELREV SPIN TIME START GUARd

STEAM STOP TIME

TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE

SLOPE FACTOR ALWAYS REVERSING ANTI-WRINKLE DELAY TIME

ANTI-WRINKLE PROGRAM ACTIVE

ANTI-WRINKLE GUARD ON TIME AUTOMATIC MODE

HEAT LOSS (OFF SET) FACTOR

GAS ONLY POWER (24VAC) IS NOT EVIDENTAT GAS VALVE NO BURNER FLAME SENSED

GAS/ELECTRIC ONLY BURNER/OVEN OPEN HI-LIMIT CIRCUIT BUZZER (TONE)

BUZ TIME

DEGREE IN CELSIUS

MAIN FUSE FAILURE

PROMPT TO CLEAN LINT SCREEN, DRYER CYCLE LOCK-OUT COOL DOWN CYCLE IN PROGRESS

COOL DOWN TIME

COOL DOWN TEMPERATURE

PREPROGRAMMED CYCLE A

PREPROGRAMMED CYCLE B

PREPROGRAMMED CYCLE C

PREPROGRAMMED CYCLE D

PREPROGRAMMED CYCLE E

PREPROGRAMMED CYCLE F

DRYING or COOLING CYCLE COMPLETE OR DRYER INANTI-WRINKLE MODE DRYINGCYCLEINPROGRESS

DRYNESS LEVEL(PERCENTAGE OF EXTRACTION) (NUMERICALVALUE) DRYING TEMPERATURE

LENGTH OF DRYING CYCLE TUMBLER HI-LIMIT CIRCUIT IS OPEN CYCLE DISPLAY TIME

SPECIFIC HEAT TYPE OR DRYER ELECTRICALLY HEATED FABRIC TEMPERATURE

DEGREE IN FAHRENHEIT

FLASH DISPLAYACTIVE

SPECIFIC HEAT TYPE OF DRYER GAS HEATED INDICATESAN OVERHEAT CONDITION

LINT DRAWER/DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. SWITCH CIRCUIT DRYING CYCLES RANGE FROM 1-10 CYCLES BEFORE CLEAN LINT DISPLAY CYCLE DISPLAY TIME

DOOR CIRCUIT IS OPEN OR FAULT IN THE A.C. DOOR SWITCH CIRCUIT MANUAL MODE

MAXIMUM GUARD TIME FLASH DISPLAY NOTACTIVE SAIL SWITCH OPEN

ANTI-WRINKLE PROGRAM IS NOT ACTIVE NO BUZZER (TONE)

GAS ONLY IGNITION ATTEMPT FAILURE NO REVERSE

NO ROTATIONAL SENSOR SELECTED PROGRAM MODE

NO CYCLE IN PROGRESS ROTATIONAL SENSOR SELECTED ROTATIONAL SENSOR CIRCUIT FAILURE

MONITORS TUMBLER RPM WITH ROTATIONAL SENSOR CIRCUIT ACTIVE GAS/ELECTRIC ONLY ATTEMPT MADE TO START DRYER WITH SAIL SWITCH DISABLED IN CLOSED POSITION

SELET REVERSE SPIN TIME

START ANTI WRINKLE GUARD CYCLE

SPECIFIC HEAT TYPE OR DRYER STEAM HEATED STOP TIME

FAULT IN M.P. HEAT SENSING CIRCUIT

48

Image 52
Contents AD-95/ML-95 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Troubleshooting Safety Precautions SectionCleaning WeeklyDays MonthsSeven Days after Installation and every 6 Months AdjustmentsLubrication Enclosure, Air Supply, and Exhaust Requirements Electrical and Gas RequirementsOperational Service Check Procedure Prior to February 11 Control Panel Microprocessor As of February 11With circuit breaker Reversing Relay Panel With fusesGas Burner Assembly HSI Module Gas ModelsDrive Motor Blower Motor and ImpellerTaperlock Trantorque Drive Shaft Assembly Idler Shaft Assembly Transtorque TaperlockMain Door Switch Basket TumblerSail Switch Gas Models Only Hi-Limit Gas Models OnlyAutomatic Reset Thermostat Lint ScreenLint Drawer Switch Servicing Computer ControlsTo Replace Keyboard Label Assembly To Remove Flame Sensor Probe Ignition ControlsHSI Ignitor Flame Sensor Probe To Replace Gas Valve See burner illustration on To Test and Adjust Gas Water Column PressureTo Replace Main Burner Orifices To Convert Natural Gas to L.P. Gas To Replace Burner TubesDiscontinue power to the dryer To Replace HSI ModuleTo Replace Sail Switch Sail Switch Assembly Gas Models OnlyTo Adjust Sail Switch To Replace Main Door Switch To Replace Main Door AssemblyTo Install New Main Door Glass as of October 24 Front Panel and Main Door AssembliesAs of October 24 Prior to October 24 To Replace Front Panel To Install new Main Door Glass prior of October 24To Replace Main Door Hinge Block Pulleys To Replace Drive Shaft Pulley To Replace Drive Motor PulleyPage Tumbler Wheel Replacement on IdlerAssembly taper lock models Tumbler Wheel Replacement on IdlerAssembly trantorque models To Replace Blower Shaft PulleyBasket Assembly To Replace Blower Motor PulleyBelt Adjustment Motor to Drive Axle To Replace Drive Assembly Pillow Block BearingTo Replace Idler Shaft Pillow Block Bearing Motors To Replace Drive Motor V-BeltsTo Replace Impeller Motor Fan Shaft Drive To Replace Blower Motor V-belts To Replace Front Thruster WheelsRear Access ImpellerTo Replace Lint Door Switch Lint Screen AssemblyTo Replace Lint Screen No display on computer Computer will not accept key pad entriesDryer will not start, but computer display indictors are on Drive motor runs, burner is on, but basket will not turnThermal overload for drive motor is tripping Burner hi-limit safety thermostat is trippingOverload for impeller fan motor is tripping There is excessive vibration coming from the basket Phase 6 OPL System Diagnostics Page E.D. Display Indicators E.D Display Indicator Number AIR AIR JET Output L.E.D. Indicator Optional FAN Blower Output L.E.D. IndicatorFuse Main Fuse Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. Indicator E.D. Codes BURNER Safety Fail DRUM Safety FailBURNER Control Fail BURNER Flame FailComputer Logic and Wiring Diagram No Display Condition Drive motor reverses but does not forward, blower motor runs Blower motor does not operate, drive motor runsLint Door Condition Main Door ConditionMicroprocessor Which Must be Reset Manually Technical Information For exampleData Label HOW to USE a Manometer AD-95/ML-95 Tool List ADC450188 1- 01/14/99-25