SECTION VIII

Technical Information

The following section contains various technical information important to the service person in servicing and maintaining the dryer.

A. MOTOR PLATE (HIGH AND LOW VOLTAGE)

The motor plate is located on the side of the drive motor (see illustration) and contains a graphical repre- sentation of the motor wiring for both low and high voltage ratings.

Removing the cap reveals the wiring to the motor. On each wire there is a number which corresponds to the numbers on the motor plate. Depending on whether the dryer is operating on low or high voltage, the wiring should match the motor plate as follows:

The dots and lines represent connections (see illustration).

For example:

 

 

On low voltage

-

wire no. 14 is connected to wire no. 4

 

-

wire no. 1 is connected to wire no. 7, which in turn are both con-

 

 

nected to L1

On high voltage

-

wire no. 14 is insulated or capped

 

-

wire no. 4 is connected to wire no. 7

 

-

wire no. 1 is connected to L1

56

Image 60
Contents AD-95/ML-95 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Content Troubleshooting Safety Precautions SectionCleaning WeeklyDays MonthsAdjustments Seven Days after Installation and every 6 MonthsLubrication Enclosure, Air Supply, and Exhaust Requirements Electrical and Gas RequirementsOperational Service Check Procedure Prior to February 11 Control Panel Microprocessor As of February 11With circuit breaker Reversing Relay Panel With fusesGas Burner Assembly HSI Module Gas ModelsDrive Motor Blower Motor and ImpellerTaperlock Trantorque Drive Shaft Assembly Idler Shaft Assembly Transtorque TaperlockMain Door Switch Basket TumblerSail Switch Gas Models Only Hi-Limit Gas Models OnlyAutomatic Reset Thermostat Lint ScreenLint Drawer Switch Servicing Computer ControlsTo Replace Keyboard Label Assembly Ignition Controls To Remove Flame Sensor ProbeHSI Ignitor Flame Sensor Probe To Test and Adjust Gas Water Column Pressure To Replace Gas Valve See burner illustration onTo Replace Main Burner Orifices To Convert Natural Gas to L.P. Gas To Replace Burner TubesDiscontinue power to the dryer To Replace HSI ModuleSail Switch Assembly Gas Models Only To Replace Sail SwitchTo Adjust Sail Switch To Replace Main Door Switch To Replace Main Door AssemblyTo Install New Main Door Glass as of October 24 Front Panel and Main Door AssembliesAs of October 24 Prior to October 24 To Install new Main Door Glass prior of October 24 To Replace Front PanelTo Replace Main Door Hinge Block Pulleys To Replace Drive Shaft Pulley To Replace Drive Motor PulleyPage Tumbler Wheel Replacement on IdlerAssembly taper lock models Tumbler Wheel Replacement on IdlerAssembly trantorque models To Replace Blower Shaft PulleyBasket Assembly To Replace Blower Motor PulleyTo Replace Drive Assembly Pillow Block Bearing Belt Adjustment Motor to Drive AxleTo Replace Idler Shaft Pillow Block Bearing To Replace Drive Motor V-Belts MotorsTo Replace Impeller Motor Fan Shaft Drive To Replace Blower Motor V-belts To Replace Front Thruster WheelsRear Access ImpellerLint Screen Assembly To Replace Lint Door SwitchTo Replace Lint Screen No display on computer Computer will not accept key pad entriesDryer will not start, but computer display indictors are on Drive motor runs, burner is on, but basket will not turnBurner hi-limit safety thermostat is tripping Thermal overload for drive motor is trippingOverload for impeller fan motor is tripping There is excessive vibration coming from the basket Phase 6 OPL System Diagnostics Page E.D. Display Indicators E.D Display Indicator Number AIR AIR JET Output L.E.D. Indicator Optional FAN Blower Output L.E.D. IndicatorFuse Main Fuse Input L.E.D. Indicator Flame bURNER Control Fail Input L.E.D. Indicator E.D. Codes BURNER Safety Fail DRUM Safety FailBURNER Control Fail BURNER Flame FailComputer Logic and Wiring Diagram No Display Condition Drive motor reverses but does not forward, blower motor runs Blower motor does not operate, drive motor runsLint Door Condition Main Door ConditionMicroprocessor Which Must be Reset Manually Technical Information For exampleData Label HOW to USE a Manometer AD-95/ML-95 Tool List ADC450188 1- 01/14/99-25