Maytag MDG-75 installation manual Timing Legend, Reversing Timer SPIN/DWELL Adjustments

Page 45

SECTION VIII

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is located in the upper rear area of the dryer.

Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

30

60

90

120

150

 

 

 

 

 

 

DWELL (STOP) TIME

 

 

 

 

 

 

 

 

 

 

 

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

5

6.3

7.6

8.9

10.2

 

 

 

 

 

 

* Values shown are +/- 1-second.

41

Image 45
Contents MDG-75 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications Component Identification Page Location Requirements Installation ProceduresUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Horizontal Venting Exhaust RequirementsSingle Dryer Venting Page Page Page Electrical Requirements Electrical InformationMDG-75 Gas Page Single-Phase 1Ø Electrical Connections Leads Page Page GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Preoperational Instructions Shut Down Instructions SERVICE/PARTS Information ServiceParts Returning Warranty Cards Warranty InformationCleaning Routine MaintenanceLubrication AdjustmentsProcedure for Functional Check Replacement Components Page Page Timing Legend Reversing Timer SPIN/DWELL AdjustmentsData Label Data Label InformationSerial Number Microprocessor Controller Computer Models TroubleshootingBlower and fan motors are not operating does not start Failed microprocessor controller computer Failed keyboard touch pad label assembly Microprocessor controller computer L.E.D. display reads Sefl Dryer operates but is taking too long to dry GAS Models AA. Condensation on main door glass Timer Models Blower/fan motors are not operating does not start GAS Models Dryer operates but is taking too long to dry Condensation on main door glass Page P O RTA N T Manual Reset HI-LIMIT Instructions