Maytag MDG-75 installation manual AA. Condensation on main door glass

Page 55

X.At the completion of the “AUTO” drying/cooling cycle, the load is coming out over dried...

1.Percent of dryness (dryness level) of the cycle selected is too high.

2.Factor “A” and Factor “B” is not set correctly or Factor “B” has to be adjusted for adverse local conditions.

Y.At the completion of the “AUTO” drying/cooling cycle, the load is still coming out damp...

1.Percent of dryness (dryness level) of the cycle selected is too low.

2.Factor “A” and Factor “B” is not set correctly or Factor “B” has to be adjusted for adverse local conditions.

Z.Main burners are burning with a yellow flame (for Gas Models ONLY)...

1.Poor air and gas mixture (too much gas or not enough air) at the burner...

a.Not enough make-up air.

b.Restriction in the exhaust ductwork.

c.Gas pressure is too high.

d.Impellor (fan and blower) is rotating in the wrong direction (for 3-phase [3ø] Models ONLY).

e.Burner orifice size (drill material size [D.M.S.]) too large for application (i.e., high elevation).

AA.Condensation on main door glass...

1.Too long, undersized, or improperly installed ductwork.

2.Back draft damper is sticking in the partially closed position.

BB.Scraping noise at basket (tumbler) area...

1.Check for obstruction caught in basket (tumbler) and wrapper area.

2.Basket (tumbler) is out of proper alignment...

a.Check both the vertical alignment and lateral alignment.

b.Check for gap between the front panel and basket (tumbler)...bearing setscrews may have come loose, and basket (tumbler) walked forward or backward.

3.Loose basket (tumbler) tie rod.

4.Failed basket (tumbler) support.

CC.Excessive noise or vibration...

1.Dryer is not leveled properly.

51

Image 55
Contents MDG-75 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications Component Identification Page Location Requirements Installation ProceduresUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Horizontal Venting Exhaust RequirementsSingle Dryer Venting Page Page Page Electrical Requirements Electrical InformationMDG-75 Gas Page Single-Phase 1Ø Electrical Connections Leads Page Page GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Preoperational Instructions Shut Down Instructions Service SERVICE/PARTS InformationParts Returning Warranty Cards Warranty InformationCleaning Routine MaintenanceLubrication AdjustmentsProcedure for Functional Check Replacement Components Page Page Timing Legend Reversing Timer SPIN/DWELL AdjustmentsData Label Data Label InformationSerial Number Microprocessor Controller Computer Models TroubleshootingBlower and fan motors are not operating does not start Failed microprocessor controller computer Failed keyboard touch pad label assembly Microprocessor controller computer L.E.D. display reads Sefl Dryer operates but is taking too long to dry GAS Models AA. Condensation on main door glass Timer Models Blower/fan motors are not operating does not start GAS Models Dryer operates but is taking too long to dry Condensation on main door glass Page P O RTA N T Manual Reset HI-LIMIT Instructions