Maytag MDG-75 installation manual GAS Models

Page 54

2.Restriction in ductwork...

a.Dryer back draft damper is sticking partially closed.

b.Restriction/obstruction in ductwork...

1)Check ductwork from dryer ALL the way to the outdoors.

3.Insufficient make-up air.

4.Impellor (fan and blower) is rotating in the wrong direction (for 3-phase [3ø] Models ONLY).

5.Lint screen is dirty or is not being cleaned often enough.

6.Inadequate airflow...

a.Impellor (fan and blower) failure.

GAS MODELS...

1)Low and/or inconsistent gas pressure.

Natural gas pressure - must be a consistent 3.5 inches (8.7 mb) of water column (W.C.).

Liquid Propane (L.P.) gas pressure - must be a consistent 10.5 inches (26.1 mb) of water column.

2)Poor air and gas mixture at burner (too much gas or not enough air) at the burner...yellow or poor flame pattern...

a)Not enough make-up air.

b)Restriction in the exhaust ductwork.

c)Gas pressure too high.

d)Impellor (fan and blower) is rotating in the wrong direction (for 3-phase [3ø] Models ONLY).

e)Burner orifice size (drill material size [D.M.S]) too large for application (i.e., high elevation).

3)Sail switch is fluttering...

a)Restriction in the exhaust ductwork...

(1)Lint screen is dirty or is not being cleaned often enough.

4)Gas supply may have too low a heating value.

NOTE: Lint accumulation on the sensor bracket can act as an insulator, which will affect the accuracy of the automatic drying cycle.

50

Image 54
Contents MDG-75 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Section Important InformationSafety Precautions What to do if YOU Smell GASPage SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Horizontal VentingSingle Dryer Venting Page Page Page Electrical Information Electrical RequirementsMDG-75 Gas Page Single-Phase 1Ø Electrical Connections Leads Page Page GAS Information Type of GAS Page Page Preparation for OPERATION/START-UP Preoperational Tests Basket Coating Preoperational Instructions Shut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsRoutine Maintenance CleaningAdjustments LubricationProcedure for Functional Check Replacement Components Page Page Reversing Timer SPIN/DWELL Adjustments Timing LegendData Label Information Data LabelSerial Number Troubleshooting Microprocessor Controller Computer ModelsBlower and fan motors are not operating does not start Failed microprocessor controller computer Failed keyboard touch pad label assembly Microprocessor controller computer L.E.D. display reads Sefl Dryer operates but is taking too long to dry GAS Models AA. Condensation on main door glass Timer Models Blower/fan motors are not operating does not start GAS Models Dryer operates but is taking too long to dry Condensation on main door glass Page Manual Reset HI-LIMIT Instructions P O RTA N T