Mitsubishi Electronics JT-SB216DS-W-AUS manual Resistance values between black and white, red

Page 10

 

Error mode display

Cause

Check procedure and action to take

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Motor

• Measure the winding resistance. (Measure the

 

 

 

LED1

LED2

 

 

 

 

resistance values between "black and white," "red and

 

Power

Inspection

 

 

 

black," and "white and red" wires of the 1-pin

 

 

 

 

 

 

 

 

connector coming from the motor.)

 

 

(Motor lock)

 

 

 

 

 

 

* Replace the motor if the measured values are other

 

 

 

 

 

 

 

 

than the normal value shown in

 

 

 

 

 

 

the table at right.

 

 

 

 

 

 

 

 

Measured value

 

Decision

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Approx. 3.4 to 3.7Ω

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Control circuit

• Replace the control circuit if other than above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Excess voltage applied

• Is a rated power supply voltage of 220 to 240 V being

 

LED1

LED2

 

 

 

 

 

 

applied?

 

 

 

 

 

Power

Inspection

 

 

2.Low voltage

 

 

 

 

 

 

 

• Is a rated power supply voltage of 220 to 240 V being

 

 

 

 

 

 

 

applied?

 

 

 

 

(Overvoltage, low voltage,

3.No power supply

 

 

 

 

• Is a power supply frequency 50 or 60 Hz?

 

 

power supply frequency

 

 

frequency

 

 

 

 

 

 

 

 

detection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.Control circuit

• Replace the control circuit if other than the above.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Control circuit

• Replace the control circuit.

 

 

 

 

 

LED1

LED2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Inspection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Microcomputer RAM abnormality)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Motor

• Measure the winding resistance. (Measure the

 

 

 

LED1

LED2

 

 

 

 

 

 

resistance values between "black and white," "red and

 

Power

Inspection

 

 

 

 

 

black," and "white and red" wires of the 1-pin

 

 

 

 

 

 

 

 

 

 

connector coming from the motor.)

 

 

(Overcurrent detection)

 

 

 

 

* Replace the motor if the measured values are other

 

 

 

 

 

 

 

 

 

 

 

 

than the normal value shown

 

 

 

 

 

 

 

 

 

 

in the table at right.

Measured value

 

Decision

 

 

 

 

 

 

 

 

 

 

 

Approx. 3.4 to 3.7Ω

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.Control circuit

• Replace the control circuit if other than above.

 

 

 

 

 

 

 

 

1.Control circuit

• Replace the control circuit.

 

LED1

LED2

 

 

 

 

Power

Inspection

 

 

 

 

 

(Current detection circuit

 

 

abnormality)

 

 

 

—10—

Image 10
Contents Hand Dryer Contents Safety precautions Turn off the powerFeatures Items to check during repair workNames and functions of the hand dryers components Specifications DimensionsWiring diagrams Troubleshooting LED1 LED2Resistance at two places between each pair Resistance values between black and white, red Replace the bottom light emitting boards and the light Reference data LED display list Description How to call Power switch Overhaul procedureTurning power off Technical notesDisplay board Control board Blower Light emitting board topLight emitting board bottom Light receiving board Precautions when replacing Product Sequence timing chart Description of circuit operation Hand detection and hand dryer operation Control of the blower motorCircuit diagram and items to check Board diagram and items to check Parts list JT-SB216DS-W-AUS Page Drain tank Page Blower cover 1962 Pcs/unit For safety 9819 35 MEE