 | Error mode display | Cause | Check procedure and action to take | |
| 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 4.Power switch | • Unplug the relay connector, and measure the | 
| 
 | LED1 | LED2 | ||
| 
 | 
 | resistance at two places between each pair of the | ||
| 
 | Power | Inspection | 
 | |
| 
 | 
 | power switch's "brown" and "blue" lead wires. | ||
| 
 | ● | ● | 
 | 
 | 
(No display, no operation)
| 
 | 
 | 
 | 
 | 5.Control circuit | • Replace the control circuit if other than above. | 
 | 
 | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 1.Display board | • Is the sensor's lead wire connector (CN2) connected? | 
 | |||||||||
| 
 | LED1 | LED2 | 
 | 
 | |||||||||||
| 
 | 
 | 
 | • Unplug the control circuit's CN2  | 
 | |||||||||||
| 
 | Power | Inspection | 
 | 
 | 
 | ||||||||||
| 
 | 
 | 
 | measure the voltage between pins 1 and 2 as well as | 
 | |||||||||||
| 
 | ● | ● | 
 | 
 | 
 | ||||||||||
| 
 | 
 | 
 | pins 1 and 3 of the CN2 by diode check (measure on | 
 | |||||||||||
| (Operates, but no display) | 
 | 
 | |||||||||||||
| 
 | the lead wire side). | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | Measured value | Decision/action | 
 | ||
| 
 | 
 | 
 | 
 | 2.Control circuit | 
 | 
 | 
 | 
 | 
 | 
 | 1.5 to 1.8V | Normal | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | • Replace the control circuit if other than above. | 
 | 
 | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 1.Filter clogged with dust | • Is the filter clogged with dust and the like? → If so, | 
 | |||||||||
| 
 | LED1 | LED2 | 
 | 
 | |||||||||||
| 
 | 
 | 
 | clean the filter. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | Power | Inspection | 
 | 2.PTC operation (control | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | • Are the temperatures of the control circuit and | 
 | 
 | |||||||||||
| 
 | ✩ | ✩ | 
 | 
 | 
 | ||||||||||
| 
 | 
 | circuit) | electronic parts too high? → If so, turn OFF the power | 
 | |||||||||||
| (Heat sink overheat) | 
 | switch and lower the temperatures to normal | 
 | 
 | |||||||||||
| 
 | 
 | 
 | 
 | 
 | temperatures (40 ˚C or less). | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 3.Control circuit | • Replace the control circuit if other than above. | 
 | 
 | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 1.Continuous operation | • When the operation time exceeds 30 seconds, the | 
 | |||||||||
| 
 | LED1 | LED2 | 
 | 
 | |||||||||||
| 
 | 
 | 
 | operation stops by the activated mischievous use | 
 | |||||||||||
| 
 | Power | Inspection | 
 | 
 | 
 | ||||||||||
| 
 | 
 | 
 | prevention timer. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | ✩ | ● | 
 | 2.Stained sensor's | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | • Are the sensor's three windows stained? | 
 | 
 | 
 | ||||||||||
| (Mischievous use | 
 | 
 | 
 | ||||||||||||
| windows | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| prevention timer) | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 3.Disengaged sensor | • Is the sensor's lead wire connector connected? | 
 | 
 | ||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||
| 
 | 
 | 
 | 
 | 4.Displaced sensor's | • Are the sensor's board positions displaced (top/bottom | 
 | |||||||||
| 
 | 
 | 
 | 
 | board positions | light emitting boards, light receiving board)? | 
 | 
 | ||||||||
| 
 | 
 | 
 | 
 | 5.Sensor light | • Measure the forward voltages of the LEDs on the | 
 | |||||||||
| 
 | 
 | 
 | 
 | emitting/receiving | top/bottom light emitting boards and the photo diode | 
 | |||||||||
| 
 | 
 | 
 | 
 | diode failure | (PHD) on the light receiving board with a measuring | 
 | |||||||||
| 
 | 
 | 
 | 
 | 
 | device that has a diode check function. | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | – side | 
 | 
 | Item name | Measured value | Decision | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | Tester | LED | 0.9 to 1.2V | Normal | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | + side | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | Photo diode | 0.5 to 0.8V | Normal | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | * Replace the top/bottom light emitting boards and the | 
| 
 | light receiving board if the measured values are | 
| 
 | other than the normal values shown in the table | 
| 
 | above. | 
| 6.Control circuit | • Replace the control circuit if other than above. | 
| 
 | 
 | 
| 
 |