Phenomena of problems other than error mode display
| Phenomenon | Cause | 
 | 
 | Check procedure and action to take | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| Lighting does not turn on. | 1.Lighting board | • Replace the light receiving board. | 
 | 
 | 
 | 
 | ||||||
| 
 | 2.Control circuit | • Replace the control board if other than above. | 
 | 
 | ||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| The hand dryer starts | 1.Stained sensor's windows | • Are the sensor's three windows stained? | 
 | 
 | ||||||||
| drying as soon as the | 2.Disengaged sensor | • Is the sensor's lead wire connector connected? | 
 | 
 | ||||||||
| power switch is turned | 3.Displaced sensor's | • Are the sensor's board positions displaced (bottom | ||||||||||
| ON. | board positions | 
 | light emitting boards, light receiving board)? | 
 | 
 | |||||||
| 
 | 4.Sensor light | • Measure the forward voltages of the LEDs on the | ||||||||||
| 
 | emitting/receiving | 
 | bottom light emitting boards and the photo diode | |||||||||
| 
 | diode failure | 
 | (PHD) on the light receiving board with a measuring | |||||||||
| 
 | 
 | 
 | device that has a diode check function. | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | – side | 
 | Item name | 
 | Measured value | 
 | Decision | 
 | |
| 
 | 
 | 
 | 
 | Tester | LED | 
 | 0.9 to 1.2V | 
 | Normal | 
 | ||
| 
 | 
 | 
 | 
 | + side | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | Photo diode | 
 | 0.5 to 0.8V | 
 | Normal | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | * Replace the bottom light emitting boards and the light | ||||||||||
| 
 | 
 | 
 | receiving board if the measured values are other than | |||||||||
| 
 | 
 | 
 | the normal values shown in the table above. | 
 | 
 | |||||||
| 
 | 5.Control circuit | • Replace the display board or the control circuit if other | ||||||||||
| 
 | 
 | 
 | than above. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | |||||||||
| The hand dryer does not | 1.Stained sensor's | • Are the sensor's three windows stained? → Clean the | ||||||||||
| stop after removing the | windows | 
 | windows if stained. | 
 | 
 | 
 | 
 | 
 | 
 | |||
| hands. | 2.Disengaged sensor | • Is the sensor's lead wire connector connected? | 
 | 
 | ||||||||
| 
 | 3.Displaced sensor's | • Are the sensor's board positions displaced? → Install | ||||||||||
| 
 | board positions | 
 | the sensor light boards in their proper positions if | |||||||||
| 
 | 
 | 
 | displaced (top light emitting boards, light receiving | |||||||||
| 
 | 
 | 
 | board). | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 4.Sensor light | • Measure the forward voltages of the LEDs on the top | ||||||||||
| 
 | emitting/receiving | 
 | light emitting boards and the photo diode (PHD) on | |||||||||
| 
 | diode failure | 
 | the light receiving board with a measuring device that | |||||||||
| 
 | 
 | 
 | has a diode check function. | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | – side | 
 | Item name | 
 | Measured value | 
 | Decision | 
 | |
| 
 | 
 | 
 | 
 | Tester | LED | 
 | 0.9 to 1.2V | 
 | Normal | 
 | ||
| 
 | 
 | 
 | 
 | + side | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | Photo diode | 
 | 0.5 to 0.8V | 
 | Normal | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | * Replace the top light emitting boards and the light | |||||||||
| 
 | 
 | 
 | receiving board if the measured values are other | |||||||||
| 
 | 5.Control circuit | 
 | than the normal values shown in the table above. | |||||||||
| 
 | • Replace the display board or the control circuit if other | |||||||||||
| 
 | 
 | 
 | than above. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| Abnormal noise is | 1.Suction of foreign | • Are foreign particles being attached to the motor's | ||||||||||
| particles | ||||||||||||
| generated. | 
 | fins? | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 2.Filter clogged with dust | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | • Is the filter clogged with dust? | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |