6. Troubleshooting

Precautions when diagnosing malfunctions:

When servicing, be sure to recreate the malfunction 2 to 3 times before initiating repairs.

When servicing, always keep proper footing.

When servicing, make sure that the cord is pulled out of the outlet, or the breaker is off if no mains connector is built in the product, so as no electrical shock or injury to occur. Pay sufficient attention when working on the product.

Always connect the power wire properly.

When removing the circuit board, always hold it at both ends and remove carefully so as not to apply force to the surface mounted parts.

When removing the circuit board, be careful of the metal edges on the board.

When inserting or extracting pin connectors on the circuit board, hold the entire housing. Do not pull on the lead wires.

If a malfunction of the printed circuit board is suspected, check for any broken copper-printed pattern, burnt or discolored parts.

Be sure to restore same settings as those on the one just replaced.

*The names of the parts indicated are compatible with those listed under the "Name of part" in the chapter "Parts list".

Description of error modes below

 

 

LED1 LED2

 

 

 

 

 

 

 

 

[] Lit

[] Blinking (0.4 sec on/0.4 sec off)

 

 

 

 

 

 

 

 

[] Unlit

[] Fast blinking (0.1 sec on/0.1 sec off)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error mode display

Cause

 

Check procedure and action to take

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Power off

 

• Is the power supply connected?

 

 

 

LED1

LED2

 

 

 

 

 

 

 

• Is the power switch on?

 

 

 

 

 

 

Power

Inspection

 

 

 

 

 

 

 

 

 

 

2.Current fuse

 

• Measure the resistance between the current fuses on

 

 

 

 

 

 

 

the control board.

 

 

 

 

 

(No display, no operation)

 

 

Measured value

Decision/action

 

 

 

 

 

 

 

 

 

 

 

 

* Replace the control board

 

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

if the measured resistance value is other than the

 

 

 

 

3.Motor temperature fuse

 

normal value shown in the table at right.

 

 

 

 

 

 

 

• Is the motor's lead wire connector connected?

 

 

 

 

 

 

• Measure the resistance between the motor's two

 

 

 

 

 

 

"blue" lead wires.

 

 

 

 

 

 

 

 

 

 

 

Measured value

Decision/action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Replace the motor if the

 

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

measured resistance value is other than the normal

 

 

 

 

 

 

value shown in the table at right.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

—8—

Image 8
Contents Hand Dryer Contents Safety precautions Turn off the powerFeatures Items to check during repair workNames and functions of the hand dryers components Specifications DimensionsWiring diagrams Troubleshooting LED1 LED2Resistance at two places between each pair Resistance values between black and white, red Replace the bottom light emitting boards and the light Reference data LED display list Description How to call Overhaul procedure Turning power offPower switch Technical notesDisplay board Control board Blower Light emitting board topLight emitting board bottom Light receiving board Precautions when replacing Product Sequence timing chart Description of circuit operation Hand detection and hand dryer operation Control of the blower motorCircuit diagram and items to check Board diagram and items to check Parts list JT-SB216DS-W-AUS Page Drain tank Page Blower cover 1962 Pcs/unit For safety 9819 35 MEE