Bradley Smoker EXD-2N Cleaning and Maintenance Instructions, Terreon and panel maintenance

Page 10

Express® Deck Lavatory System EXD-Series

 

EXD-2N

Installation Instructions

Cleaning and Maintenance Instructions

IMPORTANT: Strong alkaline or acid-based chemicals and cleansers should not be used to clean Terreon®. If these chemicals come in contact with the Terreon® surface, wipe off the surface immediately and flush with soapy water.

Terreon® and panel maintenance

The bowl is constructed of Terreon®, a densified solid surface material composed of an acrylic modified polyester resin. Terreon® is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleaners or fine grit abrasives. The panel is made of an acrylic/ABS laminate, and will not chip, peel or flake. With regular cleaning, your Terreon® fixture will provide years of dependable service.

Cleaning

Daily Cleaning: Wipe the surface with a damp cloth and wipe dry.

Weekly Cleaning: Wipe the surface with a damp cloth and a household liquid detergent. Stubborn stains can be removed as follows:

1.Using a #7448 Scotch-Brite® pad, scrub with an abrasive cleanser such as Ajax®, Comet® or Soft Scrub® and water.

2.Clean thoroughly with soapy water and allow to dry.

Scorch Marks: Although Terreon® will not burn, a lit cigarette in contact with Terreon® could leave a scorch mark. Scorch marks can be removed by buffing with a #7448 Scotch-Brite pad or with an abrasive cleaner.

Repair kit: In the unlikely event your Terreon® surface becomes damaged, it can easily be repaired. Contact your Bradley representative to order a repair kit and be sure to specify color when ordering.

Panel cleaning

IMPORTANT: Do not use abrasive cleansers to clean the panel. Abrasive cleaners can mar the surface.

Graffiti/Vandalism: If vandals create markings on the panel, Bradley recommends using Motsenbocker’s LIFT OFF® to remove ink and spray paint. Remover #3 is for ink and markers, and Remover #4 is for spray paint. Motsenbocker’s LIFT OFF® can be ordered through Sanitary Maintenance Service Inc. (call 1-800-451-5523 x 425 or visit www.santitarymaintenance.com/product.htm for ordering information). After cleaning with LIFT OFF®, give the panel a final thorough cleaning with a liquid tub and tile cleaner to remove soil and maintain the glossy finish.

NOTE: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are regional in distribution and can be found in local supermarkets, department and hardware stores or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions.

10

2/9/07

Bradley Corporation • 215-1542 Rev. E; EN 06-915

Image 10
Contents Installation Instructions Express Deck Lavatory System EXD-SeriesEXD-2N Standard Height Supplies required for installation Installation InstructionsRough EXD-2N Express Deck Lavatory System Dimensions Option #2Procedure #3 on page 4 Figure Mounting frame to wallInstalling bowl Connecting supply and drain Completing installation Optional hot water heaterCleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Panel cleaningAssembly of Components PrepackProblem Limited water flow Thermostatic Mixing Valve Maintenance and TroubleshootingProblem External leaks in the system Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259