Bradley Smoker EXD-2N Mounting frame to wall, Procedure #3 on page 4 Figure

Page 6

Express® Deck Lavatory System EXD-Series

 

EXD-2N

Installation Instructions

Installation Instructions continued . . .

Step 2: Mounting frame to wall

1.Using a T20 Torx key, remove the six #10-24 flat head Torx screws and #10 finish washers securing the access panel to the main frame, and remove the panel (Figure 2).

2.Position the frame against the wall, ensuring that it is level.

IMPORTANT: Anchoring the frame to a wall that is not flat may cause the frame to

bend, making it difficult to reinstall the access panels.

3.Ensure that the back of the frame is flat against the wall.

4.Once you have positioned the

frame such that it is level (and

MAIN FRAME

resting on the floor, standard height

 

frame only) and flat against the

 

wall, use the 3/8" bolts and 1" min.

ACCESS PANEL

O.D. washers to mount the frame

 

to the wall (Figure 3).

 

5. When mounting the standard

#10-24 PANEL FASTENERS

 

height frame, mount the scuff base

AND WASHERS

(6) PLACES

to the wall at the same time using

 

the two additional 3/8" bolts and

SCUFF PANEL

washers mentioned in Step 1,

STANDARD HEIGHT

FRAME ONLY

procedure #3 on page 4 (Figure 3).

SCUFF PANEL FASTENERS

 

 

AND WASHERS

 

(4) PLACES

 

Figure 2

*

*

3/8" WALL ANCHORS

(4) PLACES

MAIN FRAME

*

*

*

*

Figure 3

SCUFF BASE FRAME STANDARD HEIGHT FRAME ONLY

3/8" WALL ANCHORS

(2)PLACES

STANDARD HEIGHT

FRAME ONLY

6

2/9/07

Bradley Corporation • 215-1542 Rev. E; EN 06-915

Image 6
Contents Installation Instructions Express Deck Lavatory System EXD-SeriesEXD-2N Standard Height Installation Instructions Supplies required for installationRough EXD-2N Express Deck Lavatory System Dimensions Option #2Procedure #3 on page 4 Figure Mounting frame to wallInstalling bowl Connecting supply and drain Completing installation Optional hot water heaterCleaning Cleaning and Maintenance InstructionsTerreon and panel maintenance Panel cleaningAssembly of Components PrepackThermostatic Mixing Valve Maintenance and Troubleshooting Problem Limited water flowProblem External leaks in the system Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259