Bradley Smoker EXD-2N Express Deck Lavatory System Dimensions, Option #2

Page 5

 

Express® Deck Lavatory System EXD-Series

Installation Instructions

EXD-2N

 

 

EXD-2N Express® Deck Lavatory System Dimensions

Figure 1

 

 

 

 

C

 

 

23-1/2"

 

 

L

 

 

 

 

23-1/2"

 

(597mm)

 

 

(597mm)

 

 

 

13-1/4"

 

 

 

OPTION #1*

 

 

(337mm)

 

 

 

 

 

 

9-3/8"

 

9-3/8"

 

 

A

 

(238mm)

 

(238mm)

 

A

 

 

 

 

 

 

 

3"

 

4"

 

 

HOT SUPPLY

B

(76mm)

 

(102mm)

B

 

OPTION #2**

 

 

 

 

 

 

 

 

 

 

 

 

D

D

 

 

 

 

 

4"

 

E

 

 

F

 

 

 

 

 

 

(102mm)

COLD OR

 

 

 

 

G

 

TEMPERED

 

 

 

 

G

 

SUPPLY

 

 

32"

 

 

OPTION

 

 

 

 

 

 

 

28-3/4"

(813mm)

 

 

 

 

 

 

1-3/8"

 

 

 

(730mm)

 

 

 

 

B

 

B

(35mm)

 

 

 

 

 

 

 

 

 

25-3/4"

 

 

 

2" (51mm)

 

 

(654mm)

 

 

 

 

 

20"

21"

 

 

13"

 

22"

 

 

(330mm)

 

(559mm)

(508mm)

(533mm)

 

 

 

 

 

 

 

 

 

 

19"

 

 

 

15"

 

 

(483mm)

 

 

(381mm)

FLOOR

C

 

 

C

 

 

 

 

 

 

* OPTION 1 - RECOMMENDED 240V/208V OR 277V

3-1/2"

(89mm)

ELECTRICAL BOX LOCATION (4"L x 4"W x 8"H)

 

or

 

**OPTION 2 - RECOMMENDED 240V/208V OR 277V ELECTRICAL BOX LOCATION (4"L x 4"W x 4"H)

 

CHART 1

 

 

 

 

RIM HEIGHT

VERTICAL HEIGHT ADJUSTMENTS

FIXTURE STYLE

“A” THROUGH “F”

 

 

 

 

 

34"

NONE

STANDARD HEIGHT

34"

NONE

WALL HUNG

32"

SUBTRACT 2"

TAS, GRADES 6 THRU 8/9

31"

SUBTRACT 3"

JUVENILE HEIGHT

30"

SUBTRACT 4"

TAS, PRE-K THROUGH 5/6

CHART 2

CODE

DESCRIPTION

QTY.

“A”

3/8" BOWL WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 LBS.

2

 

 

 

“B”

3/8" MAIN FRAME WALL ANCHORS WITH A MINIMUM PULL-OUT FORCE OF 1,000 LBS.

6

 

 

 

“C”

3/8" BASE FRAME WALL ANCHORS, STANDARD FRAME OPTION ONLY.

2

 

 

 

“D”

1/2" NPT HOT/COLD SUPPLIES, STUB OUT 2" FROM WALL

2

 

 

 

“E”

1-1/2" NPT DRAIN, STUB OUT 2" FROM WALL

1

 

 

 

“F”

110V GFCI PROTECTED ELECTRIC OUTLET (FOR OPTIONAL ELECTRONIC FAUCETS)

1

“G”

#10 WALL ANCHORS/FASTENERS FOR OPTIONAL VERNATHERM™ VALVE MOUNTING

2

 

 

 

Bradley Corporation • 215-1542 Rev. E; EN 06-915

2/9/07

5

Image 5
Contents Express Deck Lavatory System EXD-Series Installation InstructionsEXD-2N Standard Height Rough Installation InstructionsSupplies required for installation Option #2 EXD-2N Express Deck Lavatory System DimensionsMounting frame to wall Procedure #3 on page 4 FigureInstalling bowl Connecting supply and drain Optional hot water heater Completing installationTerreon and panel maintenance Cleaning and Maintenance InstructionsCleaning Panel cleaningPrepack Assembly of ComponentsProblem External leaks in the system Thermostatic Mixing Valve Maintenance and TroubleshootingProblem Limited water flow Repair Kit S65-259 Vernatherm Thermostatic Mixing Valve S01-524