GE Monogram DCXH46, PSXH43, DSXH43, DPXH46, DH43 Exhaust Ducting Length, Exhaust Direction

Page 13

Installation Instructions

EXHAUST DUCTING LENGTH

The exhaust system should be inspected and cleaned a minimum of every year with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.

DO NOT assemble the duct work with fasteners that extend into the duct. They will serve as collection points for lint.

Insulation – Ductwork which runs through an unheated area or is near an air conditioning duct should be insulated to reduce condensation and lint buildup.

MAXIMUM LENGTH

of 4“ (10.2 cm) Dia. FLEXIBLE METAL TUBING

PREFERRED VENT HOOD TYPE

 

4” (10.2 cm)

 

Louvered

 

 

Number

 

 

 

 

 

of 90°

 

 

 

 

 

turns

4”

 

 

 

2.5”

 

 

 

 

(6.35

 

(10.2 cm)

 

 

 

cm)

0

 

30’

(9.14 m)

18’

(5.49 m)

1

 

22’

(6.71 m)

14’

(4.27 m)

2

 

14’

(4.27 m)

10’

(3.05 m)

MAXIMUM LENGTH

of 4“ (10.2 cm) Dia. RIGID METAL DUCT

PREFERRED VENT HOOD TYPE

 

4” (10.2 cm)

Louvered

 

 

Number

 

 

 

 

of 90°

 

 

 

 

turns

4”

 

 

2.5”

 

 

 

(6.35

 

(10.2 cm)

 

 

 

 

 

cm)

 

 

 

 

0

60’

(18.28 m)

48’

(14.63 m)

1

52’

(15.84 m)

40’

(12.19 m)

2

44’

(13.41 m)

32’

(9.75 m)

3

32’

(9.75 m)

24’

(7.31 m)

4

28’

(8.53 m)

16’

(4.87 m)

INSTALL MALE FITTINGS IN

CORRECT DIRECTION

CORRECT

 

 

INCORRECT

 

 

 

 

EXHAUST DIRECTION

All dryers are shipped set up for rear exhausting.

On electric dryers, exhausting can be on the cabinet right or left side, or through the dryer bottom. Gas dryers can exhaust on the cabinet right side or the dryer bottom. To change exhaust direction you will need Exhaust Kit Pub. No. 14-A018 and a rigid metal 4″ 90-degree elbow. The kit is available through your GE retailer. Follow the instructions supplied with the kit.

Same as EXHAUST DUCT LOCATING

 

other side

DIMENSIONS

 

 

5 7/8

 

 

(15 cm)

4 3/8

 

 

 

13 5/16

(11 cm)

 

(34 cm)

 

3 3/4(9.5 cm)

 

3 3/4(9.5 cm)

GAS SUPPLY REQUIREMENTS

Replace brass connecting pipe that is not plastic-coated. Stainless steel or plastic-coated brass MUST be used.

WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use NEW flexible connectors when installing a gas appliance.

1.Installation MUST conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition) or in Canada, the current CAN/CGA B149.

2.The gas supply line should be of 1/2″ (1.27 cm) rigid pipe.

3.If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass.

4.The gas supply line MUST have an individual shutoff valve.

5.A 1/8″ (0.32 cm) NPT plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer.

6.The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).

7.The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).

13

Image 13
Contents 350A4502P325 Rev 134287400 175D1807P460Two easy ways to register your appliance GE & You, a Service PartnershipFlammable vapors and liquids Do not store or use gasoline or otherVicinity of this or any other appliance Gas supplier Clear the room, building or area of all occupantsYour Laundry Area When not Using Your Dryer About the dryer control panel Features and appearance may varyFabric Care Drying CyclesWrinkle Care Option on some models About your dryer featuresReplacing the Dryer Light Bulb on some models Drying Rack on some modelsSorting and Loading Hints Loading and using the dryerRead these instructions completely and carefully Commonwealth of MassachusettsCompletion time 1-3 hours Exhausting sectionInstallation Instructions Electrical Connection Information for Electric Dryers Read these instructions completely and carefullyCorrect Incorrect Exhaust System RequirementsFollowing directions must be followed Exhaust Direction Exhaust Ducting LengthGAS Supply Requirements Allow the following clearances for ease of installation Do not install the dryer on carpetLocation of Your Dryer Custom-sized countertop is requiredSee the Exhaust System Requirements section for other Mobile Home Installation ROUGH-IN DimensionsDryer is designed under Ansi Z Grounding Requirements Electrical Installation for Electric DryersFor a grounded, cord-connected electric dryer For a permanently connected electric dryerCanada a 4-wire power supply cord is installed on the dryer Wire System for Electric DryersMust be Level and Resting Solidly on ALL Four Legs GAS Connection for GAS DryersMounting the Dryer to the Washer Tools Required for Stacking the DryerNumbers in the illustration correspond to steps Reversing the Dryer Door Swing Stacking Instructions-Reversing Door SwingBefore you call for service… Clothes take too long Static occursTo dry Clothes are wrinkledSafety Instructions GE Will Replace Model DPXH46Models DSXH43 and DH43 What GE Will Not CoverModel PSXH43 Model DCXH46Canada, call Consumer SupportCanada geappliances.ca, or write to