Installation Instructions
EXHAUST DUCTING LENGTH
The exhaust system should be inspected and cleaned a minimum of every year with normal usage. The more the dryer is used, the more often you should check the exhaust system and vent hood for proper operation.
•DO NOT assemble the duct work with fasteners that extend into the duct. They will serve as collection points for lint.
•Insulation – Ductwork which runs through an unheated area or is near an air conditioning duct should be insulated to reduce condensation and lint buildup.
MAXIMUM LENGTH
of 4“ (10.2 cm) Dia. FLEXIBLE METAL TUBING
PREFERRED VENT HOOD TYPE
| 4” (10.2 cm) |
| Louvered |
|
|
Number |
|
|
|
|
|
of 90° |
|
|
|
|
|
turns | 4” |
|
|
| 2.5” |
|
|
|
| (6.35 | |
| (10.2 cm) |
|
|
| cm) |
0 |
| 30’ | (9.14 m) | 18’ | (5.49 m) |
1 |
| 22’ | (6.71 m) | 14’ | (4.27 m) |
2 |
| 14’ | (4.27 m) | 10’ | (3.05 m) |
MAXIMUM LENGTH
of 4“ (10.2 cm) Dia. RIGID METAL DUCT
PREFERRED VENT HOOD TYPE
| 4” (10.2 cm) | Louvered |
|
|
Number |
|
|
|
|
of 90° |
|
|
|
|
turns | 4” |
|
| 2.5” |
|
|
| (6.35 | |
| (10.2 cm) |
|
| |
|
|
| cm) | |
|
|
|
| |
0 | 60’ | (18.28 m) | 48’ | (14.63 m) |
1 | 52’ | (15.84 m) | 40’ | (12.19 m) |
2 | 44’ | (13.41 m) | 32’ | (9.75 m) |
3 | 32’ | (9.75 m) | 24’ | (7.31 m) |
4 | 28’ | (8.53 m) | 16’ | (4.87 m) |
INSTALL MALE FITTINGS IN
CORRECT DIRECTION
CORRECT |
|
| INCORRECT |
|
|
|
|
EXHAUST DIRECTION
All dryers are shipped set up for rear exhausting.
On electric dryers, exhausting can be on the cabinet right or left side, or through the dryer bottom. Gas dryers can exhaust on the cabinet right side or the dryer bottom. To change exhaust direction you will need Exhaust Kit Pub. No.
Same as EXHAUST DUCT LOCATING |
| |
other side | DIMENSIONS |
|
| 5 7/8″ |
|
| (15 cm) | 4 3/8″ |
|
| |
| 13 5/16″ | (11 cm) |
| (34 cm) |
|
3 3/4″ (9.5 cm) |
| 3 3/4″ (9.5 cm) |
GAS SUPPLY REQUIREMENTS
Replace brass connecting pipe that is not
WARNING: Never reuse old flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use NEW flexible connectors when installing a gas appliance.
1.Installation MUST conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition) or in Canada, the current CAN/CGA B149.
2.The gas supply line should be of 1/2″ (1.27 cm) rigid pipe.
3.If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or
4.The gas supply line MUST have an individual shutoff valve.
5.A 1/8″ (0.32 cm) NPT plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer.
6.The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).
7.The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).
13