GE Monogram PSXH43 Electrical Installation for Electric Dryers, Grounding Requirements

Page 16

Installation Instructions

ELECTRICAL INSTALLATION FOR ELECTRIC DRYERS

WARNING: The following are specific requirements for proper and safe electrical installation of your dryer. Failure to follow these instructions can create electrical shock and/or a fire hazard.

This appliance MUST be properly grounded. Electrical shock can result if the dryer is not properly grounded. Follow the instructions in this manual for proper grounding.

DO NOT use an extension cord with this dryer. Some extension cords are not designed to withstand the amounts of electrical current this dryer utilizes and can melt, creating electrical shock and/or fire hazard. Locate the dryer within reach of the wall outlet, taking into account the length of power cord to be purchased and allowing some slack in the cord. Refer to Electrical Requirements in this manual for the proper power cord to be purchased.

A UL-listed strain relief must be installed onto power cord. If the strain relief is not attached, the cord can be pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock.

NOTE: Dryers operating on 208-volt power supply will have longer drying times than those operating

on 240-volt power supply.

A wiring diagram is located under the top panel.

GROUNDING REQUIREMENTS

WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded.

The dryer MUST be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by creating a path of least resistance for electrical current.

Grounding must be in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the National Electrical Code ANSI/NFPA No. 70.

For a grounded, cord-connected electric dryer:

If your dryer is equipped with a power supply cord having an equipment-grounding conductor and a grounding plug, the plug MUST be plugged into an appropriate, copper-wired receptacle (in the U.S.), or in Canada, an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. If in doubt, call a licensed electrician.

For a permanently connected electric dryer:

The dryer MUST be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

For a grounded, cord-connected gas dryer:

This dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Do not modify the plug on this appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

16

Image 16
Contents 175D1807P460 350A4502P325 Rev 134287400GE & You, a Service Partnership Two easy ways to register your applianceDo not store or use gasoline or other Flammable vapors and liquidsVicinity of this or any other appliance Gas supplier Clear the room, building or area of all occupantsYour Laundry Area When not Using Your Dryer Features and appearance may vary About the dryer control panelFabric Care Drying CyclesAbout your dryer features Wrinkle Care Option on some modelsReplacing the Dryer Light Bulb on some models Drying Rack on some modelsLoading and using the dryer Sorting and Loading HintsCommonwealth of Massachusetts Read these instructions completely and carefullyCompletion time 1-3 hours Exhausting sectionInstallation Instructions Read these instructions completely and carefully Electrical Connection Information for Electric DryersCorrect Incorrect Exhaust System RequirementsFollowing directions must be followed Exhaust Direction Exhaust Ducting LengthGAS Supply Requirements Do not install the dryer on carpet Allow the following clearances for ease of installationLocation of Your Dryer Custom-sized countertop is requiredSee the Exhaust System Requirements section for other Mobile Home Installation ROUGH-IN DimensionsDryer is designed under Ansi Z Electrical Installation for Electric Dryers Grounding RequirementsFor a grounded, cord-connected electric dryer For a permanently connected electric dryerWire System for Electric Dryers Canada a 4-wire power supply cord is installed on the dryerGAS Connection for GAS Dryers Must be Level and Resting Solidly on ALL Four LegsMounting the Dryer to the Washer Tools Required for Stacking the DryerNumbers in the illustration correspond to steps Stacking Instructions-Reversing Door Swing Reversing the Dryer Door SwingBefore you call for service… Static occurs Clothes take too longTo dry Clothes are wrinkledSafety Instructions Model DPXH46 GE Will ReplaceModels DSXH43 and DH43 What GE Will Not CoverModel DCXH46 Model PSXH43Canada, call Consumer SupportCanada geappliances.ca, or write to