Frigidaire 134940700A installation instructions Safety Instructions, PRE-INSTALLATION Requirements

Page 2

 

CONTENTS

Pre-Installation Requirements

2

Electrical Requirements

3

Exhaust System Requirements

3-4

Gas Supply Requirements

4-5

Location of Your Dryer

5

Rough-In Dimensions

6

Mobile Home Installation

7

Unpacking

7

Reversing Door Swing

8-9

Electrical Installation

10

Grounding Requirements

10

Electrical Connections—3-wire

11

Electrical Connections—4-wire

11

Gas Connection

12

General Installation

12

Replacement Parts

12

Español

13-24

SAFETY INSTRUCTIONS

Clothes dryer installation and service must be performed by a qualified installer, service agency or the gas supplier. Install the clothes dryer according to the manufacturer's instructions and local codes.

Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future reference.

NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian electrical code C22.1 part 1.

NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223.1, or in Canada, CAN/ACG B149.1-2000

NOTE: The Dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 No. 112 (latest editions) for HOME USE only. This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.

RISK OF FIRE. For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life. SAVE THESE INSTRUCTIONS.

-Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance.

-WHAT TO DO IF YOU SMELL GAS

·Do not try to light any appliance.

·Do not touch any electrical switch; do not use any phone in your building.

·Clear the room, building or area of all occupants.

·Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions.

·If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Your safety and the safety of others is very important.

We have provided many important safety messages in the Use & Care Guide, Operating Instructions, Installation Instructions and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you or others. All safety messages will be preceded by the safety alert symbol and the word "DANGER" or "WARNING". These words mean:

DANGER You will be killed or seriously injured if you don't follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

PRE-INSTALLATION REQUIREMENTS

Tools and Materials Required for Installation:

1.Phillips head screwdriver.

2.Channel-lock adjustable pliers.

3.Carpenter's level.

4.Flat or straight blade screwdriver.

5.Duct tape.

6.Rigid or flexible metal 4 inch (10.2 cm) duct.

7.Vent hood.

8.Pipe thread sealer (Gas).

9. Plastic knife.

2

Image 2
Contents Installation Instructions Safety Instructions PRE-INSTALLATION RequirementsNema 10-30R Nema 14-30R GAS Dryer Electrical RequirementsElectric Dryer Exhaust Direction Exhaust Duct Locating DimensionsGAS Supply Requirements Location of Your Dryer Do not Install Your DryerInstallation in Recess or Closet Sides Rear TOP FrontDryer Installation Dimensions Solid Door Reversing Instructions Mobile Home InstallationReversing Door Swing Window Door Reversal Instructions Page Electrical Installation Grounding RequirementsElectrical Connections For 3-WIRE System Electrical Connections for 4-WIRE SystemGAS Connection Replacement PartsGeneral Installation QUE Debe Hacer SI Percibe Olor a GAS Requerimientos DE Instalación PreliminaresInstrucciones Herramientas y materiales necesarios para la instalaciónSecadoras Eléctricas Requerimientos EléctricosRequerimientos DEL Sistema DE Escape Nema 10-30R Nema 14-30RUbicación DEL Escape Largo MáximoTipo DE Caperuza DE Salida No Instale SU Secadora Requerimientos DEL Suministro DE GASUbicación DE SU Secadora Instalación Dentro DE UN Nicho O ArmarioDimensiones de la Instalación Dryer Installation Dimensions Instalación EN Casas Móviles Puerta ReversiblePage Page Instalación Eléctrica Requerimientos Para LA Puesta a TierraConexiónes Eléctricas Para UN Sistema Trifilar Secadoras Eléctricas No CanadiensesConexión DEL GAS General InstalaciónPiezas DE Recambio Para Detectar SI HAY Fugas DE GAS