Frigidaire 134940700A Location of Your Dryer, Do not Install Your Dryer, Sides Rear TOP Front

Page 5

5.A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer.

6.The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).

7.The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than

1/2 psig (3.45 kPa).

LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:

1.In an area exposed to dripping water or outside weather conditions.

2.In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of combustion and ventilation air.

3.On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm).

INSTALLATION IN RECESS OR CLOSET

1.A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.

2.No other fuel burning appliance shall be installed in the same closet as the Gas dryer.

3.Your dryer needs the space around it for proper ventilation.

DO NOT install your dryer in a closet with a solid door.

4.A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

 

SIDES

REAR

TOP FRONT

Alcove

0 (0 cm)

0 (0 cm)

 

Closet

0 (0 cm)

0 (0 cm)

1 (2.54 cm)

Closet door ventilation required: 2 louvered openings each 60 square inches (387 square centimeters) — 3 inches (7.6 cm) from bottom and top of door.

This dryer MUST be exhausted outdoors.

5.The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation.

0" (0 cm)

60 sq. inches

 

(387.1 sq. cm)

0" (0 cm)

 

1" (2.54 cm)

0" (0 cm)

60 sq. inches

 

(387.1 sq. cm)

 

CLOSET DOOR

 

5

Image 5
Contents Installation Instructions PRE-INSTALLATION Requirements Safety InstructionsNema 10-30R Nema 14-30R GAS Dryer Electrical RequirementsElectric Dryer Exhaust Direction Exhaust Duct Locating DimensionsGAS Supply Requirements Installation in Recess or Closet Do not Install Your DryerLocation of Your Dryer Sides Rear TOP FrontDryer Installation Dimensions Solid Door Reversing Instructions Mobile Home InstallationReversing Door Swing Window Door Reversal Instructions Page Grounding Requirements Electrical InstallationElectrical Connections for 4-WIRE System Electrical Connections For 3-WIRE SystemGAS Connection Replacement PartsGeneral Installation Instrucciones Requerimientos DE Instalación PreliminaresQUE Debe Hacer SI Percibe Olor a GAS Herramientas y materiales necesarios para la instalaciónRequerimientos DEL Sistema DE Escape Requerimientos EléctricosSecadoras Eléctricas Nema 10-30R Nema 14-30RUbicación DEL Escape Largo MáximoTipo DE Caperuza DE Salida Ubicación DE SU Secadora Requerimientos DEL Suministro DE GASNo Instale SU Secadora Instalación Dentro DE UN Nicho O ArmarioDimensiones de la Instalación Dryer Installation Dimensions Puerta Reversible Instalación EN Casas MóvilesPage Page Requerimientos Para LA Puesta a Tierra Instalación EléctricaSecadoras Eléctricas No Canadienses Conexiónes Eléctricas Para UN Sistema TrifilarPiezas DE Recambio General InstalaciónConexión DEL GAS Para Detectar SI HAY Fugas DE GAS