Part 6 ELECTRICAL REQUIREMENTS FOR GAS DRYERS
120 Volt, 60 Hertz, with 3-Prong Grounding Plug
Following are additional instructions regarding electrical connections and requirements for gas dryers.
!Warning: The wiring and grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and all applicable local regulations. Please contact a qualified electrician to check your hom’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer. Failure to do so can result in fire or electrical shock.
Electrical Requirements for Your Dryer:
a)Please note that the wiring diagram is provided inside the dryer control hood. Label all wires prior to disconnection when servicing the dryer, because wiring errors can cause serious injury to you and your dryer.
b)Your dryer is designed to be used on a separate branch, polarized,
c)Use separately fused circuits for washers and dryers, and DO NOT operate a washer and a dryer on the same circuit.
!WARNING!
•Do not overload the circuit by operating other appliances on the same circuit when this appliance is operating, by using an extension cord to connect the dryer to the power source, or by using any adapter to allow additional cords to connect to the same outlet.
•Failure to do so can result in fire or electrical shock.
!WARNING!
•DO NOT modify the plug provided with the dryer. If it does not fit the outlet in your laundry room, a proper outlet will need to be installed in your laundry room by a qualified service person or company.
•Failure to do so can result in fire or electrical shock.
STANDARD 120 VOLT, 60 HERTZ,
1L1
2Ground
3Neutral Side
4Round Grounding Prong
5Neutral
a)The dryer has a
b)The dryer must be grounded in order to reduce the risk of electric shock, including a malfunction or breakdown.
c)If your laundry room does not meet the specifications required by this manual, or if you are uncertain whether or not your laundry room meets these specifications, please have a qualified service person or company.
Review your laundry room’s electrical supply for any problems.
2 1