HOW TO USE

CYCLE GUIDE

The cycle guide below shows the available options and recommended fabric types for AUTO DRY cycles. *NOTE: The default time and actual time will vary depending on the size of the load and moisture content.

Auto Dry Cycles

Auto Dry cycles utilize a sensor that detects moisture levels in the clothes and adjusts the drying time as needed to ensure superior results. The dryer automatically sets the dry level and temperature at the recommended setting for each cycle. The estimated time remaining will be shown in the display.

Type

AUTO DRY

 

 

 

 

 

 

 

 

 

 

 

 

 

= available option

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= default setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modifiers

 

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Time in

 

More

Wrinkle

 

Damp

 

Static

 

Iron

 

 

 

 

 

 

 

 

 

 

 

Cycle

Fabric Type

Temperature

Dry Level

 

 

Time/Less

 

Dry

 

 

 

Min.

 

Guard

 

 

Shield

 

Ready

 

 

 

 

 

 

 

 

Time

 

Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comforter, shirts, trousers

Mid high

 

Off

 

 

20

 

 

Garment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Count

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steam Refresh

1-5 garments (DO NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

use for delicate fabrics)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sanitize

Comforter, bedding,

High

 

Extra dry

 

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

children’s clothing, etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heavy Duty

Jeans, heavyweight

High

 

Normal

 

 

54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

items

 

 

Adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Casual

Permanent press,

Mid low

 

Normal

 

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

synthetic items

 

 

Adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bulky/Bedding

Comforter, pillows,

Medium

 

Normal

 

 

55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shirts

 

 

Adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

Work clothes, etc.

Medium

 

Normal

 

 

41

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Workout Wear

Workout wear

Off

 

Off

 

 

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only normal &

High

 

Normal

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Small Load

cotton/towel fabric

 

 

Adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

type (Max 3 lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delicates

Lingerie, sheets,

Mid low

 

Normal

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

blouses

 

 

Adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: To protect your garments, not every dry level, or option is available with every cycle. Temperature settings cannot be changed. A different chime will sound and the LED will not illuminate or the selection will not change if the selection is not allowed.

CERTIFIED BY NSF

NSF International (formerly the National Sanitation Foundation), certifies that the SANITIZE cycle reduces 99.9% of bacteria on laundry, and none of the bacteria will carry over onto the next laundry load.

The default settings for the SANITIZE cycle are HIGH temperature and EXTRA DRY. These default settings cannot be changed.

Do NOT use this cycle with delicate items or fabrics.

Steam cannot be added to the SANITIZE cycle.

20

Image 20
Contents Steam Dryer Features and Benefits Installation InstructionsHOW to USE Troubleshooting GuideRead ALL Instructions Before USE Basic Safety Precautions Follow basic precautions, including the following WeatherSafety Instructions for Steam Functions KEY Parts and Components KEY Dimensions and Specifications Additional instructions for closet installationsLocation Requirements Choose the Proper LocationInstallation with Optional Pedestal Base or Stacking KIT Optional AccessoriesConnecting GAS Dryers Electrical Requirements for GAS Models onlyConnecting the Gas Supply High-Altitude InstallationsGas shutoff valve must be installed within 6 ft Proceed to Venting the DryerConnecting Electric Dryers Electrical Requirements Connecting Electric Dryers Four-Wire Power CordThree-Wire Power Cord As well as all new construction after January 1Using the Duct Length Chart below Venting the Dryer Routing and Connecting DuctworkConnecting the Dryer Vent Wear gloves during installation Leveling the DryerReversing the Door Swing Hole cap Checking Venting Final Installation Check Testing Dryer Heating Control Panel Features Operating the Dryer Cycle Guide Auto Dry Cycles= default setting = available optionSorting Loads Fabric Care LabelsGroup Similar Items Loading the DryerTime and Status Display Cycle Modifier Buttons TempDRY Level Timed DRYTo recall a MY Cycle Cycle Options and Special FeaturesTo save a MY Cycle Steam Features Using the Steam Refresh cycleUsing the Static Shield option Using the Iron Ready optionSteam Features Filling the Steam FeederDrawer Pull out the drawer Lift out the steam feeder Tap waterRegular Cleaning Cleaning the ExteriorCleaning the Interior Cleaning Around and Under the DryerCheck Vent Indicator Maintaining the Exhaust SystemMaintaining the Exhaust System Check Vent OperationUsing the Kenmore Connect System Kenmore Connect SystemBefore Calling for Service Problem Possible Cause SolutionsBefore Calling for Service Problem Possible Cause Solutions DryClothes are wrinkled Clothes are shrinkingDisplay shows error Steam Features NotCode tE1 or tE2 Lint on clothes WorkingKenmore Elite Limited Warranty Disclaimer of implied warranties limitation of remedies