Heat Input/Gas Consumption/Orifice (Injector) Data (For Non CE [European] Models Only)

Gas Specifications for Non-CE Approved Dryers**

Model

Gas

Nominal

Supply

Gross

Orifice Size

Orifice

Burner

Heating Value

Pressure

Heat Input

 

 

(Injector)

Pressure

 

Type

 

 

 

 

 

 

Quantity

 

 

Btu/ft3

in wc

Btu/hr

kW

DMS

mm

in wc

 

 

T20

Natural

1,000

7.0-13.0

40,000

11.72

30

3.264

1

3.0

*Liquid Propane

2,500

11.0

40,000

11.72

49

1.854

1

10.0

 

T30

Natural

1,000

7.0-13.0

55,000

16.12

20

4.089

1

3.0

*Liquid Propane

2,500

11.0

55,000

16.12

44

2.184

1

10.0

 

T50

Natural

1,000

7.0-13.0

90,000

26.38

29

3.454

2

3.0

*Liquid Propane

2,500

11.0

90,000

26.38

47

2.994

2

10.0

 

T75

Natural

1,000

7.0-13.0

110,000

32.24

22

3.988

2

3.0

*Liquid Propane

2,500

11.0

110,000

32.24

44

2.184

2

10.0

 

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

Heat Input/Gas Consumption/Orifice (Injector) Data (For CE [European] Models Only)

Gas Specifications for CE Approved Dryers**

 

Gas

Nominal

Supply

Gross

Fuel

Orifice Size

Orifice

Burner

Model

Heating Value

Pressure

Heat Input

(Injector)

Pressure

Type

Consumption

 

 

 

 

 

 

 

 

 

Quantity

 

 

 

Btu/ft3

mb

Btu/hr

kW

 

DMS

mm

mb

 

Natural (I2 H/I2E )

1,000

15-30

40,000

11.72

1.133 M3/H

30

3.264

1

6.7

 

Natural (I2 L )

830

20-35

40,000

11.72

1.365 M3/H

30

3.264

1

9.2

 

Natural (I2 E L L )

830

15-30

40,000

11.72

1.365 M3/H

30

3.264

1

9.2

T20

*Natural (I2E+)

1,000

20

40,000

11.72

1.133 M3/H

38

2.578

1

830

25

40,000

11.72

1.365 M3/H

38

2.578

1

 

 

*Butane (I3+)

3,175

28-30

40,000

11.72

0.845 kg/H

52

1.613

1

 

*Propane (I3 +)

2,500

37

40,000

11.72

0.845 kg/H

52

1.613

1

 

Butane (I3 B /P )

3,175

28-30/50

40,000

11.72

0.845 kg/H

49

1.854

1

18.0

 

Propane (I3 P )

2,500

28-30/50

40,000

11.72

0.845 kg/H

49

1.854

1

23.0

 

Natural (I2 H/I2E )

1,000

15-30

55,000

16.12

1.557 M3/H

22

3.988

1

6.9

 

Natural (I2 L )

830

20-35

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

 

Natural (I2 E L L )

830

15-30

55,000

16.12

1.876 M3/H

22

3.988

1

9.5

 

*Natural (I2E+)

1,000

20

55,000

16.12

1.557 M3/H

31

3.048

1

T30

830

25

55,000

16.12

1.876 M3/H

31

3.048

1

 

 

*Butane (I3+)

3,175

28-30

55,000

16.12

1.162 kg/H

48

1.930

1

 

*Propane (I3 +)

2,500

37

55,000

16.12

1.162 kg/H

48

1.930

1

 

Butane (I3 B /P )

3,175

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

18.1

 

Propane (I3 P )

2,500

28-30/50

55,000

16.12

1.162 kg/H

44

2.184

1

24.9

 

Natural (I2 H/I2E )

1,000

15-30

90,000

26.38

2.549 M3/H

29

3.454

2

7.2

 

Natural (I2 L )

830

20-35

90,000

26.38

3.071 M3/H

29

3.454

2

8.9

 

Natural (I2 E L L )

830

15-30

90,000

26.38

3.071 M3/H

29

3.454

2

8.9

 

*Natural (I2E+)

1,000

20

90,000

26.38

2.549 M3/H

35

2.794

2

T50

830

25

90,000

26.38

3.071 M3/H

35

2.794

2

 

 

*Butane (I3+)

3,175

28-30

90,000

26.38

1.901 kg/H

50

1.778

2

 

*Propane (I3 +)

2,500

37

90,000

26.38

1.901 kg/H

50

1.778

2

 

Butane (I3 B /P )

3,175

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

18.1

 

Propane (I3 P )

2,500

28-30/50

90,000

26.38

1.901 kg/H

47

1.994

2

24.9

 

Natural (I2 H/I2E )

1,000

15-30

110,000

32.24

3.115 M3/H

22

3.988

2

6.9

 

Natural (I2 L )

830

20-35

110,000

32.24

3.753 M3/H

22

3.988

2

9.5

 

Natural (I2 E L L )

830

15-30

110,000

32.24

3.753 M3/H

22

3.988

2

9.5

 

*Natural (I2E+)

1,000

20

110,000

32.24

3.115 M3/H

31

3.048

2

T75

830

25

110,000

32.24

3.753 M3/H

31

3.048

2

 

 

*Butane (I3+)

3,175

28-30

110,000

32.24

2.324 kg/H

48

1.930

2

 

*Propane (I3 +)

2,500

37

110,000

32.24

2.324 kg/H

48

1.930

2

 

Butane (I3 B /P )

3,175

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

18.1

 

Propane (I3 P )

2,500

28-30/50

110,000

32.24

2.324 kg/H

44

2.184

2

24.9

Shaded areas are stated in metric equivalents

*Gas valve’s internal regulator disabled.

**Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.

22

JLA Limited

113429 - 9

Image 22
Contents T20 / T30 / T50 / T75 Installation/Operator Manual JLA LimitedRetain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only T20 Specifications 33.02 cmT20 Specifications T30 Specifications 37.78 cmT30 Specifications T50 Specifications 40.64 cmT50 Specifications T75 Specifications T75 Specifications Location Requirements Installation ProceduresUnpacking/Setting Up Dryer Enclosure RequirementsExhaust Requirements Fresh Air Supply RequirementsDomestic Type I T20, T30, T50 Only Horizontal Venting Outside Ductwork ProtectionSingle Dryer Venting Vertical VentingElectrical Information Electrical RequirementsT30 Electrical Service Specifications Gas Models OnlyT20 T50Grounding Single-Phase 1ø Wiring Connections/HookupElectric Models Only Electrical ConnectionsTwo Element Configuration Three Element Configuration Electrically Heated Models OnlyGas Information CE DryersDMS T20 T50 Piping/ConnectionsConverting from One Family Gas to Another Regulated Gas Valve Gas Pressure AdjustmentConversion from Propane or Butane Gas to Natural Gas Steam Information Gas Pressure TestingGas Pressure Test Procedure Steam Coil pH LevelWater Information Preparation for Operation/Start-Up Preoperational TestPreoperational Instructions Service/Parts InformationWarranty Information Coin ModelsRoutine Maintenance Data Label Information Standard Label CE Label07/15/08