American Dryer Corp T75, T30, T50 manual T20 Specifications, 33.02 cm

Page 6

T20 Specifications __________________________________________________________________

 

MAXIMUM CAPACITY (DRY WEIGHT)

 

20 lb

 

9.07 kg

 

TUMBLER DIAMETER

 

25-3/4”

 

65.41 cm

 

TUMBLER DEPTH

 

 

 

24”

 

60.96 cm

 

TUMBLER VOLUME

 

 

 

7-1/2 cu ft

212.38 L

 

TUMBLER/DRIVE MOTOR

 

1/4 hp

 

0.19 kW

 

BLOWER/FAN MOTOR

 

1/3 hp

 

0.25 kW

 

DOOR OPENING (DIAMETER)

 

19-3/8”

 

49.21 cm

 

DOOR SILL HEIGHT

 

 

 

13”

 

33.02 cm

 

WATER CONNECTION

 

3/4”-11.5 NH (North America)

 

 

 

 

 

 

 

3/4” B.S.P.T. (Outside North America)

 

DRYERS PER 20’/40’ CONTAINER

 

 

42 / 84

 

 

DRYERS PER 48’/53’ TRUCK

 

 

96 / 108

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

245 lb

 

111.13 kg

 

 

APPROXIMATE SHIPPING WEIGHT

265 lb

 

120.20 kg

 

Gas

AIRFLOW

 

 

60 Hz

230 cfm

 

6.51 cmm

 

 

 

 

 

50 Hz

191 cfm

 

5.40 cmm

 

 

 

 

 

 

 

 

 

HEAT INPUT

 

 

 

40,000 Btu/hr

10,080 kcal/hr

 

 

EXHAUST CONNECTION (DIAMETER)

4”

 

10.16 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

INLET PIPE CONNECTION

 

 

3/8” M.N.P.T.

 

 

 

 

 

 

 

 

3/8” M.B.S.P.T. (CE and Australia Only)

 

 

VOLTAGE AVAILABLE

 

200-416V

1,3ø

2,3,4w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

245 lb

 

111.13 kg

 

 

APPROXIMATE SHIPPING WEIGHT

265 lb

 

120.20 kg

 

 

AIRFLOW

 

 

60 Hz

230 cfm

 

6.51 cmm

 

 

 

 

 

 

50 Hz

191 cfm

 

5.40 cmm

 

Electric

EXHAUST CONNECTION (DIAMETER)

4”

 

10.16 cm

 

5.6

 

19,112

 

4,816

 

N / A

 

 

 

COMPRESSED AIR CONNECTION

 

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

 

 

OVEN SIZE

 

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

 

4.1

 

13,843

 

3,488

 

 

 

 

 

 

5.0

 

17,065

 

4,300

 

 

 

 

 

 

5.4

 

18,430

 

4,644

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.1

 

20,819

 

5,246

 

 

 

 

 

 

6.5

 

22,184

 

5,590

 

 

 

 

 

 

6.8

 

23,208

 

5,848

 

 

 

 

 

 

7.4

 

25,255

 

6,364

 

 

 

 

 

 

7.5

 

25,597

 

6,450

 

 

 

 

 

 

8.1

 

27,644

 

6,966

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

253 lb

 

114.76 kg

 

Steam

APPROXIMATE SHIPPING WEIGHT

273 lb

 

123.83 kg

 

AIRFLOW

 

 

60 Hz

230 cfm

 

6.51 cmm

 

 

 

 

 

50 Hz

191 cfm

 

5.40 cmm

 

 

 

 

 

 

 

 

 

STEAM CONSUMPTION

 

45 lb/hr

 

20.41 kg/hr

 

 

OPERATING STEAM PRESSURE

150 psi max

10.34 bar

 

 

EXHAUST CONNECTION (DIAMETER)

4”

 

10.16 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

BOILER HORSEPOWER (NORMAL LOAD)

1.2 Bhp

 

 

 

 

 

SUPPLY CONNECTION

 

1/2” F.N.P.T.

 

 

 

 

RETURN CONNECTION

 

1/2” F.N.P.T.

 

 

 

Shaded areas are stated in metric equivalents

 

 

 

5/1/06

Note

!The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

6

JLA Limited

113429 - 9

Image 6
Contents T20 / T30 / T50 / T75 Installation/Operator Manual JLA LimitedRetain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only T20 Specifications 33.02 cmT20 Specifications T30 Specifications 37.78 cmT30 Specifications T50 Specifications 40.64 cmT50 Specifications T75 Specifications T75 Specifications Location Requirements Installation ProceduresUnpacking/Setting Up Dryer Enclosure RequirementsFresh Air Supply Requirements Exhaust RequirementsDomestic Type I T20, T30, T50 Only Horizontal Venting Outside Ductwork ProtectionSingle Dryer Venting Vertical VentingElectrical Information Electrical RequirementsT30 Electrical Service Specifications Gas Models OnlyT20 T50Grounding Single-Phase 1ø Wiring Connections/HookupElectric Models Only Electrical ConnectionsTwo Element Configuration Three Element Configuration Electrically Heated Models OnlyGas Information CE DryersDMS T20 T50 Piping/ConnectionsConverting from One Family Gas to Another Gas Pressure Adjustment Regulated Gas ValveConversion from Propane or Butane Gas to Natural Gas Steam Information Gas Pressure TestingGas Pressure Test Procedure Steam Coil pH LevelWater Information Preparation for Operation/Start-Up Preoperational TestPreoperational Instructions Service/Parts InformationWarranty Information Coin ModelsRoutine Maintenance Data Label Information Standard Label CE Label07/15/08