American Dryer Corp T75, T20, T50 manual T30 Specifications, 37.78 cm

Page 8

T30 Specifications __________________________________________________________________

 

MAXIMUM CAPACITY (DRY WEIGHT)

 

30 lb

 

13.61 kg

 

TUMBLER DIAMETER

 

30”

 

76.20 cm

 

TUMBLER DEPTH

 

 

 

27”

 

68.58 cm

 

TUMBLER VOLUME

 

 

 

11.04 cu ft

312.62 L

 

TUMBLER/DRIVE MOTOR

 

1/4 hp

 

0.19 kW

 

BLOWER/FAN MOTOR

 

1/2 hp

 

0.37 kW

 

DOOR OPENING (DIAMETER)

 

19-3/8”

 

49.21 cm

 

DOOR SILL HEIGHT

 

 

 

14-7/8”

 

37.78 cm

 

WATER CONNECTION

 

3/4”-11.5 NH (North America)

 

 

 

 

 

 

 

3/4” B.S.P.T. (Outside North America)

 

DRYERS PER 20’/40’ CONTAINER

 

 

12 / 28

 

 

DRYERS PER 48’/53’ TRUCK

 

 

34 / 38

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

285 lb

 

129.27 kg

 

 

APPROXIMATE SHIPPING WEIGHT

310 lb

 

140.61 kg

 

Gas

AIRFLOW

 

 

60 Hz

360 cfm

 

10.19 cmm

 

 

 

 

 

50 Hz

300 cfm

 

8.49 cmm

 

 

 

 

 

 

 

 

 

HEAT INPUT

 

 

 

55,000 Btu/hr

13,860 kcal/hr

 

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

INLET PIPE CONNECTION

 

 

1/2” M.N.P.T.

 

 

 

 

 

 

 

 

3/8” M.B.S.P.T. (CE and Australia Only)

 

 

VOLTAGE AVAILABLE

 

200-416V

1,3ø

2,3,4w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

285 lb

 

129.27 kg

 

 

APPROXIMATE SHIPPING WEIGHT

310 lb

 

140.61 kg

 

 

AIRFLOW

 

 

60 Hz

360 cfm

 

10.19 cmm

 

Electric

 

 

 

 

50 Hz

300 cfm

 

8.49 cmm

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

 

 

 

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

 

 

OVEN SIZE

 

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

 

7.9

 

26,962

 

6,794

 

 

 

 

 

 

8.3

 

28,327

 

7,138

 

 

 

 

 

 

9.0

 

30,716

 

7,740

 

 

 

 

 

 

11.3

 

38,566

 

9,719

 

 

 

 

 

 

12.4

 

42,320

 

10,665

 

 

 

 

 

 

12.5

 

42,661

 

10,751

 

 

 

 

 

 

13.5

 

46,074

 

11,611

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

120-240V

2w

50/60 Hz

 

 

APPROXIMATE NET WEIGHT

 

305 lb

 

138.35 kg

 

Steam

APPROXIMATE SHIPPING WEIGHT

330 lb

 

149.69 kg

 

AIRFLOW

 

 

60 Hz

360 cfm

 

10.19 cmm

 

 

 

 

 

50 Hz

300 cfm

 

8.49 cmm

 

STEAM CONSUMPTION

 

63 lb/hr

 

28.58 kg/hr

 

OPERATING STEAM PRESSURE

150 psi max

10.34 bar

 

EXHAUST CONNECTION (DIAMETER)

6”

 

15.24 cm

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

COMPRESSED AIR VOLUME

 

 

N / A

 

 

 

BOILER HORSEPOWER (NORMAL LOAD)

 

1.75 Bhp

 

 

 

SUPPLY CONNECTION

 

 

1/2” F.N.P.T.

 

 

 

RETURN CONNECTION

 

 

1/2” M.N.P.T.

 

 

Shaded areas are stated in metric equivalents

 

 

 

9/30/05

Note

! The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.

8

JLA Limited

113429 - 9

Image 8
Contents T20 / T30 / T50 / T75 Installation/Operator Manual JLA LimitedRetain This Manual in a Safe Place for Future Reference Table of Contents Safety Precautions What To Do If You Smell GasCE only T20 Specifications 33.02 cmT20 Specifications T30 Specifications 37.78 cmT30 Specifications T50 Specifications 40.64 cmT50 Specifications T75 Specifications T75 Specifications Installation Procedures Unpacking/Setting UpLocation Requirements Dryer Enclosure RequirementsDomestic Type I T20, T30, T50 Only Fresh Air Supply RequirementsExhaust Requirements Outside Ductwork Protection Single Dryer VentingHorizontal Venting Vertical VentingElectrical Information Electrical RequirementsElectrical Service Specifications Gas Models Only T20T30 T50Single-Phase 1ø Wiring Connections/Hookup Electric Models OnlyGrounding Electrical ConnectionsTwo Element Configuration Three Element Configuration Electrically Heated Models OnlyGas Information CE DryersDMS T20 T50 Piping/ConnectionsConverting from One Family Gas to Another Conversion from Propane or Butane Gas to Natural Gas Gas Pressure AdjustmentRegulated Gas Valve Gas Pressure Testing Gas Pressure Test ProcedureSteam Information Steam Coil pH LevelWater Information Preparation for Operation/Start-Up Preoperational TestService/Parts Information Warranty InformationPreoperational Instructions Coin ModelsRoutine Maintenance Data Label Information Standard Label CE Label07/15/08