American Dryer Corp T50, T75, T30, T20 manual Data Label Information, Standard Label CE Label

Page 31

Data Label Information _____________________________________________________________

Standard Label

CE Label

When contacting JLA, the information on the data label is required to ensure proper service/parts assistance. The data label is located at the upper left rear of the dryer behind the back guard.

1.Model Number – This describes the style of dryer and type of heat (gas, electric, or steam).

2.Serial Number – Allows the manufacturer to gather information on your particular dryer.

3.Type of Heat – This describes the type of heat for your particular dryer, gas (either natural gas or L.P. gas), electric, or steam.

4.Heat Input (For Gas Dryers) – This describes the heat input in British thermal units per hour (Btu/hr) or kilowatts (kW).

5.Orifice Size (For Gas Dryers) – Gives the number drill size used.

6.Electric Service – This describes the voltage and current rating for a particular model.

7.Gas Manifold Pressure (For Gas Dryers) – This describes the manifold pressure taken at the gas valve tap.

113429 - 9

Telephone 01422 822282

31

Image 31
Contents JLA Limited T20 / T30 / T50 / T75 Installation/Operator ManualRetain This Manual in a Safe Place for Future Reference Table of Contents What To Do If You Smell Gas Safety PrecautionsCE only 33.02 cm T20 SpecificationsT20 Specifications 37.78 cm T30 SpecificationsT30 Specifications 40.64 cm T50 SpecificationsT50 Specifications T75 Specifications T75 Specifications Dryer Enclosure Requirements Installation ProceduresUnpacking/Setting Up Location RequirementsExhaust Requirements Fresh Air Supply RequirementsDomestic Type I T20, T30, T50 Only Vertical Venting Outside Ductwork ProtectionSingle Dryer Venting Horizontal VentingElectrical Requirements Electrical InformationT50 Electrical Service Specifications Gas Models OnlyT20 T30Electrical Connections Single-Phase 1ø Wiring Connections/HookupElectric Models Only GroundingElectrically Heated Models Only Two Element Configuration Three Element ConfigurationCE Dryers Gas InformationDMS Piping/Connections T20 T50Converting from One Family Gas to Another Regulated Gas Valve Gas Pressure AdjustmentConversion from Propane or Butane Gas to Natural Gas Steam Coil pH Level Gas Pressure TestingGas Pressure Test Procedure Steam InformationWater Information Preoperational Test Preparation for Operation/Start-UpCoin Models Service/Parts InformationWarranty Information Preoperational InstructionsRoutine Maintenance Standard Label CE Label Data Label Information07/15/08