Alliance Laundry Systems 602004144 manual Single Drop Control, SD and SX Control Suffixes

Page 15

Operating Instructions

25C

TMB2120N

Figure 5

Single Drop Control

SD and SX Control Suffixes

1.Select HIGH, MED, LOW or NO HEAT by turning the temperature knob.

HIGH temperature 190°F (87°C) MED temperature 160°F (71°C) LOW temperature 130°F (54°C)

2.Insert the coin(s) in the coin slot.

3.Press START button to start tumble dryer.

IMPORTANT: To stop the tumble dryer at any time during the cycle, OPEN DOOR. To restart the tumble dryer, CLOSE door and press START button.

NOTE: If display show an error code, refer to Error Codes section.

4.When the cycle is complete, open door and remove the laundry.

NOTE: This machine includes an extended tumble feature. Starting 20 minutes after a cycle ends, the cylinder will tumble for two minutes every hour without heat, up to 18 hours or until door is opened.

Preliminary Control Information

Power-Up Mode

When power is applied to the tumble dryer the control will enter Ready Mode, unless a cycle was in process prior to a disruption of power. If a power disruption is less than 5 seconds, with a cycle in process, the control will enter Run Mode once power is restored and continue the cycle. If a power disruption is more than 5 seconds, with a cycle in process, the control will enter Start Mode once power is restored.

If the dry time dipswitch settings have not changed from the factory default, the IN USE LED will flash two to five times, depending on model.

Ready Mode

In Ready Mode, the control waits for the vend to be satisfied before entering Start Mode.

Start Mode

In Start Mode, the vend has been satisfied, but the Start button has not been pressed. The IN USE LED will be lit. The timer will not count down until the Start button is pressed.

Run Mode

In Run Mode, the control is running a cycle. The IN USE LED is lit.

70400101 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

13

Image 15
Contents Tumble Dryers Page Mise EN Garde Contents Introduction Model IdentificationGas Steam Electric Customer Service Wiring DiagramSerial Plate Location Explanation of Safety Messages Safety InformationImportant Safety Instructions W055R1 Operating Instructions Emergency Stop Button on CE ModelsOperating Instructions Control Instructions LED OPL ControlEO Control Suffix QT Control Suffix Dual Digital Timer ControlOperating Instructions Display Definition Corrective Action Error CodesSD and SX Control Suffixes Single Drop ControlTo Program a Short Test Cycle Door Open ModeEnd of Cycle Mode Temperature Selector Switch3V and 3X Control Suffixes DX4 Coin Control3O Control Suffix DX4 OPL ControlIgnition Control Operation for Non- CE Models Lockout Manual Reset Standby ModeStart Up Mode Lockout ModeFlame Monitoring Unexpected Presence of FlameDaily MaintenanceMaintenance Annually MonthlyQuarterly Bi-AnnuallyMonthly Maintenance Daily MaintenanceQuarterly Maintenance Annual Maintenance Bi-Annually MaintenanceNot Dry Before You Call for Service