Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumble dryer before servicing.

Close gas shut-off valve to gas tumble dryer before servicing.

Close steam valve to steam tumble dryer before servicing.

Never start the tumble dryer with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded.

W002R1

Monthly

1.Remove lint and debris from inside exhaust duct to maintain proper airflow and avoid overheating.

a.Remove external duct and duct access covers, if present.

b.Clean inside of duct with a vacuum.

c.Clean dampers and make sure they operate freely.

d.Replace duct and all access covers before returning tumble dryer to operation.

2.Ensure even lint distribution over lint screen, replace if distribution of lint is uneven to maintain proper airflow and avoid overheating.

3.Carefully wipe any accumulated lint off the cabinet high limit thermostat and thermistor, including perforated cover. Lint buildup will act as an insulator, causing machine to overheat.

4.Clean lint and debris buildup from blower to maintain proper airflow, avoid overheating and prevent possible vibration.

Quarterly

1.Use a vacuum to clean air vents on drive motors.

2.Use a vacuum to clean lint from rear limit thermostat cover.

3.Check and clean steam coils, if applicable.

4.Check flow of combustion and ventilation air.

5.Check belt tension and condition. Replace worn or cracked belts.

Bi-Annually

1.Check mounting hardware for any loose nuts, bolts or screws.

2.Check gas connections for leakage.

3.Check for loose electrical connections.

4.Check steam connections for looseness and leakage.

5.Remove all front panels and vacuum, including coin drop mechanisms.

6.Check cylinder and front panel seals.

7.Inspect cabinet and inner panels for any damage, replace or repair as needed.

8.Clean burner tubes and orifice area of any lint buildup.

Annually

1.Remove cylinder. Use a vacuum to clean lint from area around rear seal and idler assembly. Check seal idler assembly for wear.

2.Remove burner tubes and clean using water and a brush.

22

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70400101 (EN)

Image 24
Contents Tumble Dryers Page Mise EN Garde Contents Introduction Model IdentificationGas Steam Electric Customer Service Wiring DiagramSerial Plate Location Safety Information Explanation of Safety MessagesImportant Safety Instructions W055R1 Operating Instructions Emergency Stop Button on CE ModelsOperating Instructions Control Instructions LED OPL ControlEO Control Suffix Dual Digital Timer Control QT Control SuffixOperating Instructions Error Codes Display Definition Corrective ActionSingle Drop Control SD and SX Control SuffixesDoor Open Mode End of Cycle ModeTemperature Selector Switch To Program a Short Test CycleDX4 Coin Control 3V and 3X Control SuffixesDX4 OPL Control 3O Control SuffixIgnition Control Operation for Non- CE Models Standby Mode Start Up ModeLockout Mode Lockout Manual ResetUnexpected Presence of Flame Flame MonitoringMaintenance DailyMaintenance Monthly QuarterlyBi-Annually AnnuallyDaily Maintenance Monthly MaintenanceQuarterly Maintenance Bi-Annually Maintenance Annual MaintenanceBefore You Call for Service Not Dry