Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumble dryer before servicing.

Close gas shut-off valve to gas tumble dryer before servicing.

Close steam valve to steam tumble dryer before servicing.

Never start the tumble dryer with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded.

W002R1

Bi-Annually Maintenance

Check mounting hardware for any loose nuts, bolts or screws.

Check gas connections for leakage.

Check for loose electrical connections.

Check steam connections for looseness and leakage.

Remove all front panels and vacuum, including coin drop mechanisms.

Check cylinder and front panel seals.

Inspect cabinet and inner panels for any damage, replace or repair as needed.

Clean burner tubes and orifice area of any lint buildup.

Annual Maintenance

Remove cylinder. Use a vacuum to clean lint from area around rear seal and idler assembly. Check seal and idler assembly for wear.

Remove burner tubes and clean using water and a brush.

70400101 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

25

Image 27
Contents Tumble Dryers Page Mise EN Garde Contents Introduction Model IdentificationGas Steam Electric Customer Service Wiring DiagramSerial Plate Location Explanation of Safety Messages Safety InformationImportant Safety Instructions W055R1 Operating Instructions Emergency Stop Button on CE ModelsOperating Instructions Control Instructions LED OPL ControlEO Control Suffix QT Control Suffix Dual Digital Timer ControlOperating Instructions Display Definition Corrective Action Error CodesSD and SX Control Suffixes Single Drop ControlTo Program a Short Test Cycle Door Open ModeEnd of Cycle Mode Temperature Selector Switch3V and 3X Control Suffixes DX4 Coin Control3O Control Suffix DX4 OPL ControlIgnition Control Operation for Non- CE Models Lockout Manual Reset Standby ModeStart Up Mode Lockout ModeFlame Monitoring Unexpected Presence of FlameDaily MaintenanceMaintenance Annually MonthlyQuarterly Bi-AnnuallyMonthly Maintenance Daily MaintenanceQuarterly Maintenance Annual Maintenance Bi-Annually MaintenanceNot Dry Before You Call for Service