Alliance Laundry Systems 602004144 manual Ignition Control Operation for Non- CE Models

Page 19

Ignition Control Operation for Non- CE Models

Power Up

When power is applied to the ignition control, the control will begin the ignition sequence within 1 – 3 seconds prepurge waiting time.

Ignition Sequence

The control begins the ignition sequence after prepurge by powering the ignitor and opening the gas valve. The ignitor will remain on either until a flame is sensed or until a maximum of ten (10) seconds

(10 +0/-4 sec) has elapsed. If a flame is established and lost during the 10 second period, the ignitor will be powered up again in an attempt to re-ignite the gas.

If no flame is detected within the ten (10) second ignition sequence, the control will terminate power to the gas valves, ignitor, and enter lockout within 5 seconds.

Normal Operation

Once a flame has been established, the spark ignitor will stop sparking and the control will continually monitor all inputs. If the controller senses a loss of flame after flame is established, the gas valve will remain energized and sparking will commence within one second of the flame loss. If flame reattempt fails, lockout will occur within 11 seconds of initial flame loss.

Termination of Flame

Normal flame termination occurs when the thermostat has been satisfied, meaning there is no immediate need for more heat. The thermostat will disconnect power from the ignition control, which will cause the gas valve to close and the flame to go out. After a short period of time, not less than 1 second, the thermostat will cool down and close causing power to be reapplied to the ignition control. When this occurs, the control must complete the same prepurge and ignition sequence specified above.

Operating Instructions

Control Lockout

When the control locks out, the gas valve will be closed and all requests for heat will be ignored. The lockout mode may only be discontinued by interrupting power to the control or cycling the thermostat. After this occurs, the control will restart with its normal power up and ignition sequence.

Low Voltage Detection

Low Voltage Detection The control will have capability for detection of a low voltage input condition. If input voltage on power up is below 19.0VAC +0.8VAC/-0.5VAC, the control will disable output to gas valve control relay. If input voltage rises above 19.8VAC for at least three (3) seconds, the control will then re-enable function of the gas valve control relay and ignition sequence may begin. On powerup, the control function must always be disabled if greater than 19.8VAC.

70400101 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

17

Image 19
Contents Tumble Dryers Page Mise EN Garde Contents Model Identification IntroductionGas Steam Electric Wiring Diagram Customer ServiceSerial Plate Location Explanation of Safety Messages Safety InformationImportant Safety Instructions W055R1 Emergency Stop Button on CE Models Operating InstructionsOperating Instructions LED OPL Control Control InstructionsEO Control Suffix QT Control Suffix Dual Digital Timer ControlOperating Instructions Display Definition Corrective Action Error CodesSD and SX Control Suffixes Single Drop ControlTo Program a Short Test Cycle Door Open ModeEnd of Cycle Mode Temperature Selector Switch3V and 3X Control Suffixes DX4 Coin Control3O Control Suffix DX4 OPL ControlIgnition Control Operation for Non- CE Models Lockout Manual Reset Standby ModeStart Up Mode Lockout ModeFlame Monitoring Unexpected Presence of FlameDaily MaintenanceMaintenance Annually MonthlyQuarterly Bi-AnnuallyMonthly Maintenance Daily MaintenanceQuarterly Maintenance Annual Maintenance Bi-Annually MaintenanceNot Dry Before You Call for Service