Alliance Laundry Systems 907003062 manual Position and Level the Tumble Dryer

Page 20

Installation

Position and Level the Tumble Dryer

The tumble dryer may be moved with or without the skid. To remove the skid, unscrew the four shipping bolts, and discard them.

To fit a 170 pound tumble dryer (with shipping skid) through an 8 foot (2.43 meters) high door, you must remove the front access panel. The upper 3 inches (76 mm) of the stove must also be removed on

170 pound gas tumble dryers. Removing the entire gas or steam heater assembly and the shipping skid, will reduce the height of the 120 pound tumble dryer to 70 inches (1778 mm), and the 170 pound tumble dryer to 75 inches (1905 mm).

Level the tumble dryer to within 0.125 inch (3 mm) from front-to-rear (level on cylinder rib), and side-to- side (level on top panel). Shim under corners to level and stabilize unit. Tumble dryer must not rock.

Before Placing Tumble Dryer into Service

1.Remove or open all panels and check accessible bolts, nuts, screws, terminals and fittings for tightness.

2.Check V-belt tension and adjust if necessary. Refer to appropriate paragraphs in Adjustments Section.

3.Replace all panels and guards.

4.Turn on electrical supply to tumble dryer.

5.Open supply valve for gas or steam heated tumble dryers.

6.After performing the previous checks, start the tumble dryer by pressing START (hold for approximately 3 seconds). Release the start button and open the loading door. The cylinder should stop rotating within 7 seconds after the door is opened.

7.Gas tumble dryers: Start the tumble dryer and check the burner flame. Adjust the gas inlet shutter as required. Refer to Adjustments section.

IMPORTANT: The Electronic Ignition system will attempt to light the gas by sparking for the “trial for ignition” period. If gas does not ignite within this period, the ignition control will go into a safety lockout and the valve will no longer open until the control is reset. Refer to Table 1. It may be necessary to restart several times to bleed air out of gas lines. To reset, open and close loading door, then start.

 

Prepurge

Trial for

Reset

 

Lockout

Location

Time

Ignition

Condition

 

(seconds)

(seconds)

 

By:

 

 

 

 

 

 

 

 

 

 

Press and

 

 

 

hold reset

CE and

18

10

button on

Australia

 

 

junction box

 

 

 

until light

 

 

 

goes out.

 

 

 

 

All others

1-3

10

Open loading

door.

 

 

 

 

 

 

 

 

Table 1

 

If lockout condition persists, check that the manual gas shut-off valve is in the open position and that the gas service is properly connected. If condition still persists, remove tumble dryer from service.

8.Load the cylinder with a full load of clean rags and run to remove oil or dirt from cylinder.

18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70420801 (EN)

Image 20
Contents Tumble Dryers Page What to do if YOU Smell GAS For Your Safety Contents Installing Steam Trap and Making Condensate Customer Service Wiring Diagram LocationIntroduction Model IdentificationConversion Table Multiply To Obtain Serial Plate LocationIntroduction Safety Information Important Safety Instructions Safety InformationW055R1 Specifications and Dimensions Pound Tumble Dryer Dimensions and Exhaust Outlet Locations Specifications and DimensionsCabinet Dimensions Models 120L/N/E Exhaust Outlet Dimensions and Locations Models 120L/N/ECabinet Dimensions Models 170L/N/S Exhaust Outlet Dimensions and Locations Models 170L/N/SElectric and Gas Connection Locations for Gas Models Models Electrical Connection Gas Connection120L/N 170L/NModels Electrical Connection 120S Electric and Steam Connection Locations for Steam Models170S Electric Connection Location for Electric Models Models 120EInstallation Pre-Installation InspectionLocation Requirements Materials Required Obtain locally All ModelsInstallation Before Placing Tumble Dryer into Service Position and Level the Tumble DryerRequired for CE Models Only Installing CE Gas Drying Tumble Dryers General InformationSupply Burner Country Gas Type Group Orifice Quantity Pressure Orifice Code MbarBasic Configuration Specific Conversion Procedures How to Adjust Gas Valve Governor/Regulator Exhaust Requirements LayoutMake-Up Air VentingAlternate Venting for 120 Pound tumble dryers Exhaust RequirementsIndividual Venting Duct Diameter Equivalent Length Rigid Straight DuctTMB2361N ONE Manifold Assembly Duct Pound Stations Mm DuctTWO Manifold Assemblies Gas Requirements Gas Requirements Gas Supply Pipe Sizing and Looping .4 mm Gas Pipe LoopSizes shown in inches mm 300,000 400,000500,000 600,000Gas Rate Feet Inches Quantity High Altitude Orifice SizingNon-CE Models Altitude Orifice New Electrical Requirements Grounding InstructionsFor CE Models Only Electrical RequirementsService/Ground Location Ground and Terminal Block LocationsNon-CE GasElectric To Connect Electrical Service to the Tumble Dryer Jumper Configuration Instructions Ferrite Ring InstallationElectrical Requirements Steam Requirements Piping RecommendationsThermal Oil Prep Steam RequirementsPounds Condensate/Hour Pound Tumble DryersModel Steam Pressure Minimum Steam Trap Size 80-100 4 in. NPT 517 Based on maximum psi Adjustments Gas Burner Air ShutterAirflow Switch Loading Door SwitchAdjustments Loading Door StrikeBelt Drive Removing Tumble Dryer from Service

907003062 specifications

Alliance Laundry Systems has long been recognized as a leader in the commercial laundry industry, providing innovative solutions that enhance operational efficiency and user experience. One of its standout offerings is the Alliance Laundry Systems model 907003062. This model is a robust piece of equipment designed for high-performance washing needs in a variety of commercial settings, from laundromats to hotel and institutional laundry facilities.

At the heart of the 907003062 is its powerful motor that ensures efficient and effective cleaning performance. The model features a high extraction speed, which not only reduces drying time but also helps to save energy. This efficiency is critical for high-volume operations looking to optimize workflow and reduce utility costs.

The design of the 907003062 prioritizes user-friendliness. It comes equipped with an intuitive control panel that allows operators to easily select washing cycles and settings. This feature significantly reduces the learning curve, enabling staff to become proficient quickly. Programmable settings allow businesses to customize wash programs to cater to various fabric types, ensuring garments receive the appropriate treatment without sacrificing cleanliness or quality.

Durability is another hallmark of the 907003062. Constructed with high-quality materials, this model is built to withstand the rigors of constant use in a busy commercial environment. The components are designed to resist wear and tear, ensuring longevity and reliability. This makes it a sound investment for businesses looking to avoid frequent maintenance or replacement costs.

Additionally, the 907003062 incorporates advanced technologies that promote water and energy conservation. This commitment to sustainability helps businesses reduce their environmental footprint while also appealing to the eco-conscious consumer. Features such as automatic water level adjustment and efficient detergent usage contribute to lowering operational costs.

In summary, the Alliance Laundry Systems 907003062 is a well-rounded commercial washing machine that excels in performance, durability, and efficiency. With its powerful motor, user-friendly controls, customized wash programs, and energy-saving technologies, it is an ideal solution for businesses seeking to enhance their laundry operations while maintaining high standards of cleanliness and sustainability. As commercial laundry needs evolve, models like the 907003062 set the benchmark for excellence in the industry.