Alliance Laundry Systems 907003062 manual Supply Burner Country Gas Type Group Orifice

Page 23

 

 

 

 

 

 

 

 

 

Installation

Gases and Configurations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

 

Burner

 

 

 

 

Burner

Country

Gas Type

Group

 

Orifice

Capacity/

Diameter,

Quantity

 

Pressure,

 

 

Orifice

Code

 

 

mbar

 

Pressure,

Model

mm

 

 

Part No.

 

 

 

 

mbar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DK/NO/

Natural Gas

E

20

 

8.9

120

4.8

3

 

M411372

 

 

 

 

8.0

170

4.8

4

 

M411372

SE/FI/CZ/

 

 

 

 

 

EE/LV/LT/

 

 

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

 

No Governor

120

2.6

3

 

M411376

SI/SK

 

 

 

 

 

170

3.4

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

E

20

 

8.9

120

4.8

3

 

M411372

 

 

 

 

 

8.0

170

4.8

4

 

M411372

 

 

 

 

 

 

 

 

 

 

DE**

L.P. Gas

B/P

30 and No

Governor or 26.4

120

2.6

3

 

M411376

 

 

 

 

or

170

3.4

3

 

M400997

 

 

 

 

 

 

 

 

 

50** and No Governor or

 

 

 

 

 

 

 

 

 

28.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

LL

25

 

12.0

120

4.8

3

 

M411372

NL

 

 

 

 

 

170

4.8

4

 

M411372

 

 

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

 

No Governor

120

2.6

3

 

M411376

 

 

 

 

 

 

 

 

 

170

3.4

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

E+

20

 

No Governor

120

3.7

3

 

M400998

 

 

 

 

 

 

170

3.7

4

 

M400998

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

No Governor

120

3.9

3

 

M402997

BE/FR*

 

 

 

 

 

170

3.9

4

 

M402997

 

 

 

 

 

 

 

 

 

 

L.P. Gas

3+

30

 

No Governor

120

3.0

3

 

M401017

 

 

 

 

 

 

 

 

 

170

3.5

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

 

No Governor

120

3.1

3

 

70070903

 

 

 

 

 

 

170

3.5

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

GB/IE/PT/

Natural Gas

E

20

 

8.9

120

4.8

3

 

M411372

 

 

 

 

8.0

170

4.8

4

 

M411372

ES/IT/GR/

 

 

 

 

 

 

 

 

 

 

L.P. Gas

3+

28 or 37

 

No Governor

120

2.6

3

 

M411376

LU/CH

 

 

 

 

 

 

 

 

170

3.4

3

 

M400997

 

Natural Gas

E

20

 

8.9

120

4.8

3

 

M411372

AT**

 

 

 

 

8.0

170

4.8

4

 

M411372

 

 

 

 

 

 

 

 

 

 

L.P. Gas

B/P

50**

 

26.4

120

2.6

3

 

M411376

 

 

 

 

 

 

 

 

28.7

170

3.4

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

CY/IS/MT

L.P. Gas

B/P

30

 

No Governor

120

2.6

3

 

M411376

 

 

 

 

 

170

3.4

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

25

 

8.9

120

4.8

3

 

M411372

HU

 

 

 

 

8.0

170

4.8

4

 

M411372

 

 

 

 

 

 

 

 

 

 

L.P. Gas

B/P

30

 

No Governor

120

2.6

3

 

M411376

 

 

 

 

 

 

 

 

 

170

3.4

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

 

Natural Gas

H

20

 

8.9

120

4.8

3

 

M411372

PL

 

 

 

 

8.0

170

4.8

4

 

M411372

 

 

 

 

 

 

 

 

 

 

L.P. Gas

3P

37

 

No Governor

120

2.6

3

 

M411376

 

 

 

 

 

 

 

 

 

170

3.4

3

 

M400997

 

 

 

 

 

 

 

 

 

 

 

Burner orifice information at 0-2000 feet (0-600 meters) altitude.

*For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace burner orifices.

Table 2

**For L.P. Gas, Group B/P with 50 mbar supply pressure, convert using Natural Gas model and appropriate burner orifices.

70420801 (EN)

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

21

Image 23
Contents Tumble Dryers Page What to do if YOU Smell GAS For Your Safety Contents Installing Steam Trap and Making Condensate Model Identification Customer ServiceWiring Diagram Location IntroductionConversion Table Multiply To Obtain Serial Plate LocationIntroduction Safety Information Safety Information Important Safety InstructionsW055R1 Specifications and Dimensions Exhaust Outlet Dimensions and Locations Models 120L/N/E Pound Tumble Dryer Dimensions and Exhaust Outlet LocationsSpecifications and Dimensions Cabinet Dimensions Models 120L/N/EExhaust Outlet Dimensions and Locations Models 170L/N/S Cabinet Dimensions Models 170L/N/S170L/N Electric and Gas Connection Locations for Gas ModelsModels Electrical Connection Gas Connection 120L/NModels Electrical Connection 120S Electric and Steam Connection Locations for Steam Models170S Models 120E Electric Connection Location for Electric ModelsMaterials Required Obtain locally All Models InstallationPre-Installation Inspection Location RequirementsInstallation Position and Level the Tumble Dryer Before Placing Tumble Dryer into ServiceRequired for CE Models Only General Information Installing CE Gas Drying Tumble DryersQuantity Pressure Orifice Code Mbar Supply Burner Country Gas Type Group OrificeBasic Configuration Specific Conversion Procedures How to Adjust Gas Valve Governor/Regulator Venting Exhaust RequirementsLayout Make-Up AirExhaust Requirements Alternate Venting for 120 Pound tumble dryersDuct Diameter Equivalent Length Rigid Straight Duct Individual VentingTMB2361N Duct Pound Stations Mm Duct ONE Manifold AssemblyTWO Manifold Assemblies Gas Requirements Gas Requirements .4 mm Gas Pipe Loop Gas Supply Pipe Sizing and Looping600,000 Sizes shown in inches mm 300,000400,000 500,000Gas Rate Feet Inches Quantity High Altitude Orifice SizingNon-CE Models Altitude Orifice New Grounding Instructions Electrical RequirementsElectrical Requirements For CE Models OnlyGas Service/Ground LocationGround and Terminal Block Locations Non-CEElectric To Connect Electrical Service to the Tumble Dryer Ferrite Ring Installation Jumper Configuration InstructionsElectrical Requirements Piping Recommendations Steam RequirementsSteam Requirements Thermal Oil PrepPounds Condensate/Hour Pound Tumble DryersModel Steam Pressure Minimum Steam Trap Size 80-100 4 in. NPT 517 Based on maximum psi Gas Burner Air Shutter AdjustmentsLoading Door Strike Airflow SwitchLoading Door Switch AdjustmentsBelt Drive Removing Tumble Dryer from Service

907003062 specifications

Alliance Laundry Systems has long been recognized as a leader in the commercial laundry industry, providing innovative solutions that enhance operational efficiency and user experience. One of its standout offerings is the Alliance Laundry Systems model 907003062. This model is a robust piece of equipment designed for high-performance washing needs in a variety of commercial settings, from laundromats to hotel and institutional laundry facilities.

At the heart of the 907003062 is its powerful motor that ensures efficient and effective cleaning performance. The model features a high extraction speed, which not only reduces drying time but also helps to save energy. This efficiency is critical for high-volume operations looking to optimize workflow and reduce utility costs.

The design of the 907003062 prioritizes user-friendliness. It comes equipped with an intuitive control panel that allows operators to easily select washing cycles and settings. This feature significantly reduces the learning curve, enabling staff to become proficient quickly. Programmable settings allow businesses to customize wash programs to cater to various fabric types, ensuring garments receive the appropriate treatment without sacrificing cleanliness or quality.

Durability is another hallmark of the 907003062. Constructed with high-quality materials, this model is built to withstand the rigors of constant use in a busy commercial environment. The components are designed to resist wear and tear, ensuring longevity and reliability. This makes it a sound investment for businesses looking to avoid frequent maintenance or replacement costs.

Additionally, the 907003062 incorporates advanced technologies that promote water and energy conservation. This commitment to sustainability helps businesses reduce their environmental footprint while also appealing to the eco-conscious consumer. Features such as automatic water level adjustment and efficient detergent usage contribute to lowering operational costs.

In summary, the Alliance Laundry Systems 907003062 is a well-rounded commercial washing machine that excels in performance, durability, and efficiency. With its powerful motor, user-friendly controls, customized wash programs, and energy-saving technologies, it is an ideal solution for businesses seeking to enhance their laundry operations while maintaining high standards of cleanliness and sustainability. As commercial laundry needs evolve, models like the 907003062 set the benchmark for excellence in the industry.