Pre-Installation Inspection

Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton or cover is damaged or signs of possible damage are evident, have the carrier note the condition on the shipping papers before the shipping receipt is signed, or advise the carrier of the condition as soon as it is discovered.

Remove the crate and protective cover as soon as possible and check the items listed on the packing list. Advise the carrier of any damaged or missing articles as soon as possible. A written claim should be filed with the carrier immediately if articles are damaged or missing.

IMPORTANT: Warranty is void unless tumble dryer is installed according to instructions in this manual. Installation should comply with minimum specifications and requirements detailed in this manual and applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.

Materials Required (Obtain locally)

All Models

One Single Pole fused disconnect

 

switch or circuit breaker on 1 Phase

 

models.

 

Circuit breaker on 3 Phase models.

 

 

Gas Models

One gas shut-off valve for gas

 

service line to each tumble dryer.

 

 

Steam Models

One steam shut-off valve for steam

 

service line to be connected upstream

 

of solenoid steam valve.

 

Two steam shut-off valves for each

 

condensate return line.

 

Flexible steam hoses with a 125 psig

 

(pounds per square inch gauge)

 

(8.79 kg/sq. cm) working pressure

 

for connecting steam coils. Refer to

 

Figure 14 and Figure 15 or sizing

 

and connection configurations.

 

Three steam traps for steam coil

 

outlet to condensate return line.

 

Optional – Three vacuum breakers

 

for condensate return lines.

 

 

IMPORTANT: Keep tumble dryer area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

Location Requirements

The tumble dryer must be installed on a level floor. Floor covering materials such as carpeting or tile must be removed.

To assure compliance, consult local building code requirements. The tumble dryer must not be installed or stored in area where it will be exposed to water and/ or weather.

IMPORTANT: DO NOT block the airflow at the rear of the tumble dryer with laundry or other articles. Doing so would prevent adequate air supply to the combustion chamber of the tumble dryer.

A typical tumble dryer enclosure is shown in Figure 1. Note the minimum and maximum dimensions. Local codes and ordinances must be complied with.

16

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

70420801 (EN)

Image 18
Contents Tumble Dryers Page What to do if YOU Smell GAS For Your Safety Contents Installing Steam Trap and Making Condensate Introduction Customer ServiceWiring Diagram Location Model IdentificationSerial Plate Location IntroductionConversion Table Multiply To Obtain Safety Information Important Safety Instructions Safety InformationW055R1 Specifications and Dimensions Cabinet Dimensions Models 120L/N/E Pound Tumble Dryer Dimensions and Exhaust Outlet LocationsSpecifications and Dimensions Exhaust Outlet Dimensions and Locations Models 120L/N/ECabinet Dimensions Models 170L/N/S Exhaust Outlet Dimensions and Locations Models 170L/N/S120L/N Electric and Gas Connection Locations for Gas ModelsModels Electrical Connection Gas Connection 170L/NElectric and Steam Connection Locations for Steam Models 170SModels Electrical Connection 120S Electric Connection Location for Electric Models Models 120ELocation Requirements InstallationPre-Installation Inspection Materials Required Obtain locally All ModelsInstallation Before Placing Tumble Dryer into Service Position and Level the Tumble DryerRequired for CE Models Only Installing CE Gas Drying Tumble Dryers General InformationSupply Burner Country Gas Type Group Orifice Quantity Pressure Orifice Code MbarBasic Configuration Specific Conversion Procedures How to Adjust Gas Valve Governor/Regulator Make-Up Air Exhaust RequirementsLayout VentingAlternate Venting for 120 Pound tumble dryers Exhaust RequirementsIndividual Venting Duct Diameter Equivalent Length Rigid Straight DuctTMB2361N ONE Manifold Assembly Duct Pound Stations Mm DuctTWO Manifold Assemblies Gas Requirements Gas Requirements Gas Supply Pipe Sizing and Looping .4 mm Gas Pipe Loop500,000 Sizes shown in inches mm 300,000400,000 600,000High Altitude Orifice Sizing Non-CE Models Altitude Orifice NewGas Rate Feet Inches Quantity Electrical Requirements Grounding InstructionsFor CE Models Only Electrical RequirementsNon-CE Service/Ground LocationGround and Terminal Block Locations GasElectric To Connect Electrical Service to the Tumble Dryer Jumper Configuration Instructions Ferrite Ring InstallationElectrical Requirements Steam Requirements Piping RecommendationsThermal Oil Prep Steam RequirementsPound Tumble Dryers Model Steam Pressure Minimum Steam Trap SizePounds Condensate/Hour 80-100 4 in. NPT 517 Based on maximum psi Adjustments Gas Burner Air ShutterAdjustments Airflow SwitchLoading Door Switch Loading Door StrikeBelt Drive Removing Tumble Dryer from Service

907003062 specifications

Alliance Laundry Systems has long been recognized as a leader in the commercial laundry industry, providing innovative solutions that enhance operational efficiency and user experience. One of its standout offerings is the Alliance Laundry Systems model 907003062. This model is a robust piece of equipment designed for high-performance washing needs in a variety of commercial settings, from laundromats to hotel and institutional laundry facilities.

At the heart of the 907003062 is its powerful motor that ensures efficient and effective cleaning performance. The model features a high extraction speed, which not only reduces drying time but also helps to save energy. This efficiency is critical for high-volume operations looking to optimize workflow and reduce utility costs.

The design of the 907003062 prioritizes user-friendliness. It comes equipped with an intuitive control panel that allows operators to easily select washing cycles and settings. This feature significantly reduces the learning curve, enabling staff to become proficient quickly. Programmable settings allow businesses to customize wash programs to cater to various fabric types, ensuring garments receive the appropriate treatment without sacrificing cleanliness or quality.

Durability is another hallmark of the 907003062. Constructed with high-quality materials, this model is built to withstand the rigors of constant use in a busy commercial environment. The components are designed to resist wear and tear, ensuring longevity and reliability. This makes it a sound investment for businesses looking to avoid frequent maintenance or replacement costs.

Additionally, the 907003062 incorporates advanced technologies that promote water and energy conservation. This commitment to sustainability helps businesses reduce their environmental footprint while also appealing to the eco-conscious consumer. Features such as automatic water level adjustment and efficient detergent usage contribute to lowering operational costs.

In summary, the Alliance Laundry Systems 907003062 is a well-rounded commercial washing machine that excels in performance, durability, and efficiency. With its powerful motor, user-friendly controls, customized wash programs, and energy-saving technologies, it is an ideal solution for businesses seeking to enhance their laundry operations while maintaining high standards of cleanliness and sustainability. As commercial laundry needs evolve, models like the 907003062 set the benchmark for excellence in the industry.