ADC AD-360X2 manual Electrical and GAS Requirements, Electrical Requirements

Page 11

B.ELECTRICAL AND GAS REQUIREMENTS

1.Electrical Requirements

It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

2.Grounding

A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The ground connection may be to a proven earth ground at the location service panel.

IMPORTANT: Failure to comply with these codes or ordinances and/or the requirements stipulated in this manual can result in personal injury or component failure.

3.Gas Information

It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION.

4.Gas Supply

The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI Z2231-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1 M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances and must be done by a qualified professional.

5.Piping Connections

ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance Btus being supplied.

WARNING: NEVER TEST FOR LEAKS WITH A FLAME!!!

NOTE: Undersized gas piping will result in ignition problems and slow drying and can create a safety hazard.

7

Image 11
Contents AD-360X2 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Data Label Information Important Information Safety PrecautionsSuggested Interval Routine MaintenanceCleaning AS Required AdjustmentsENCLOSURE, AIR SUPPLY, and Exhaust Requirements Installation RequirementsElectrical Requirements Electrical and GAS RequirementsOperational Service Check Procedure Coin BOX Description of PartsControl Panel Control and Relay PanelsBasket Tumbler Door Switch Hinge BlockMicroprocessor Assembly Basket Tumbler and Drive Motor Assembly ArrangementDrive Motor and Idler Pulley Arrangement Idler ARM and Impellor Mount AssemblyTemperature Sensors HI-LIMIT Thermostat Sail SwitchGAS Burner Lint Drawer Lint Drawer SwitchFront Thruster Wheel Bracket Assembly Rear Basket Tumbler Drive Wheels Rotational Sensor AssemblyTo Replace Computer ServiceIntroduction Controls ComputerTo Replace Coin Acceptor To Replace Keyboard Touch PADTo Replace GAS Valve To Replace the Ignitor Probe Burner Controls GAS To Test and Adjust GAS Water Column W.C. Pressure To Convert from Natural to Liquid Propane L.P. GAS To Replace HI-LIMIT Thermostat Thermostats and Temperature SensorTo Replace Direct Spark Ignition DSI Module To Remove the Temperature Sensor or High Heat Protector To Adjust Sail Switch Sail Switch AssemblyTo Replace Sail Switch To Replace Main Door Hinge Blocks To Replace Main Door SwitchTo Install NEW Main Door Glass Front Panel and Main Door AssembliesTo Replace the Nylon Catch To Replace Front PanelTo Replace Rotational Sensor Switch Basket Tumbler Wheel Removal Basket Tumbler RemovalGeneral System Information BCD-1 Type ModuleVAC Transformer Page Lockout Until power is removed From control 760 Direct Spark Ignition DSI FlowchartTest Equipment TroubleshootingDSI Ignitor GAP Feeler Gauge 1/8 Page Page First Visual Check Second Visual Check Third Visual Check For Leaks Withaflame Blink Green Continuously Continuously Page For 120 VAC application only ADC PN 128927 5N7 Redundant GAS Valve Direct Spark Ignition DSI System Components Diagnostics L.E.D. Display Failure Codes TroubleshootingPhase 5 Coin System Diagnosis Page D. Display Indicators No Heat Condition Blower is on Page No Start Condition 115 VAC No Display ConditionDSFL Display Condition DOOr Display Condition Data Label Data Label InformationHOW to USE a Manometer ADC PN Using a ManometerLight Emitting Diode L.E.D. Display Codes Page Page ADC450213 1 08/18/03-25
Related manuals
Manual 38 pages 18.19 Kb

AD-360X2 specifications

The ADC AD-360X2 is a high-performance audio component designed for audiophiles and professionals who demand quality and reliability. This digital-to-analog converter (DAC) is engineered to deliver superior sound quality, with an emphasis on precision and clarity.

One of the standout features of the AD-360X2 is its dual DAC architecture, which utilizes two high-end digital-to-analog chips to ensure a pristine audio output. This design not only enhances the audio resolution but also minimizes noise and distortion, resulting in a richer listening experience. The device supports high-resolution formats, including DSD and PCM, enabling users to enjoy their music in the highest quality available.

The AD-360X2 also boasts a wide range of connectivity options, allowing it to interface seamlessly with various audio devices. It includes USB, optical, and coaxial inputs, making it compatible with computers, CD players, and digital media players. This versatility means that users can easily integrate the AD-360X2 into their existing audio setup, enhancing their overall experience.

Another impressive characteristic of the AD-360X2 is its built-in headphone amplifier. This feature allows users to connect their headphones directly to the unit, providing an optimized listening experience without the need for additional equipment. The headphone amplifier is designed to drive a wide range of headphone impedances, ensuring compatibility with everything from high-impedance studio headphones to more consumer-oriented options.

Additionally, the AD-360X2 integrates advanced clock technology to enhance timing accuracy. The precision clock circuit works to reduce jitter, which is often a major source of distortion in digital audio systems. By ensuring that the signal is processed with impeccable timing, the device further elevates audio quality.

User-friendliness is another significant aspect of the AD-360X2. The device features a straightforward control interface, with an easy-to-read display that provides real-time information about the audio being played. This simplicity ensures that both novices and seasoned audio enthusiasts can operate the device with ease.

In conclusion, the ADC AD-360X2 is an exemplary digital-to-analog converter that combines high-end audio performance with user-friendly features. Its dual DAC architecture, extensive connectivity options, built-in headphone amplifier, and advanced clock technology make it a standout choice for anyone seeking to elevate their audio experience. Whether for personal use or professional applications, the AD-360X2 is engineered to meet and exceed the expectations of discerning audio lovers.