American Dryer Corp MD-170 manual Blower impellor/fan motor is not operating does not start

Page 48

continued from page 43

3.Failed drive motor.

4.Failed microprocessor controller (computer).

C.Drive motor (reversing) operates in one direction only...stops and restarts in same direction...

1.Failed drive motor contactor (relay).

2.Failed arc suppressor (A.S.) board.

3.Failed microprocessor controller (computer).

D.Drive motor operates okay for a few minutes, and then stops and will not restart...

1.Motor is overheating and tripping out on internal overload protector ...

a.Motor air vents clogged with lint.

b.Low voltage to the motor.

c.Failed motor.

d.Tumbler (basket), is binding ... check for obstruction.

e.Failed idler bearings or tumbler bearings.

E.Blower (impellor/fan) motor is not operating (does not start)...

1.Failed blower (impellor/fan) motor contactor (relay).

2.Failed arc suppressor (A.S.) board.

3.Failed blower (impellor/fan) motor.

4.Failed microprocessor controller (computer).

F.Blower motor operates okay for a few minutes, then stops and will not restart...

1.Motor is overheating and tripping out on internal overload protector ...

a.Motor air vents clogged with lint.

b.Low voltage to the motor.

c.Failed motor.

d.Failed blower (impellor/fan) drive shaft bearings.

NOTE: V-belts too tight or bearings not lubricated often enough.

44

Image 48
Contents MD-170 Installation/Operators Manual Maytag CoRetain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASGAS Supply or the Steam Supply Before ANY Covers or Specifications / Component Identification Specifications GAS and SteamSpecifications MDG-170 Gas MDS-170 Steam Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Round duct can now be connected to the dryer Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Create a Potential Fire HazardPage Page Page Page Page Electrical Information MDG-170 Gas MDS-170 Steam Page Page GAS Information Type of GAS Latest Edition Page Steam Information Steam Requirements High PressureSteam Damper System Diagram 621 kPaPage Switch Otherwise the Dryer will not Start Preparation for OPERATION/START-UPPreoperational Tests Natural Gas Inches W.C .5 millibars Shut Down Instructions Basket CoatingCompressed AIR Requirements 621 kPaSERVICE/PARTS Information ServiceParts Warranty Information Returning Warranty CardsRoutine Maintenance CleaningClean the lint drawer or screen every third or fourth load Createa Potentialfire Hazard Adjustments LubricationTroubleshooting Drive motor is not operating does not startBlower impellor/fan motor is not operating does not start Failed blower impellor/fan drive shaft bearingsFailed microprocessor controller computer Failed keyboard touchpad label assembly GAS Models Steam Models Dryer operates but is taking too long to dry Gas Models Condensation on main door glass Dryer or scraping noise at tumbler basket area AA. Excessive noise and/or vibrationFailed drive motor contactor relay Failed motor Failed blower impellor/fan drive shaft bearings Steam Models Gas Models Steam Models Condensation on main door glass Excessive noise and/or vibration Reversing Timer SPIN/DWELLADJUSTMENTS Timing LegendData Label Location / Information Data Label GAS Manifold Pressure for GAS DryersProcedure for Functional Check Replacement Components Microprocessor computer BoardModels manufactured with ADC module Part No Theory Of Operation P O R T a N T ADC P/N114501 02/16/00-25 2- 02/25/00-250