B. ADJUSTMENTS

7 Days After Installation and Every 6 Months Thereafter

Inspect bolts, nuts, screws (bearing set screws), non-permanent gas connections (unions, shut-off valves, orifices, and grounding connections). Motor and drive belts should be examined. Cracked or seriously frayed belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of controls and valves. Complete operational check of ALL safety devices (door switch, lint drawer switch, sail switch, burner, and hi-limit thermostats).

C. LUBRICATION

The motor bearings, idler bearings...and under normal/most conditions the tumbler bearings are permanently lubricated. It is physically possible to relubricate the tumbler bearings if you choose to do so even though this practice is not necessary. Use Shell Alvania #3 or its equivalent. The tumbler bearings used in the dryer do not have a grease fitting. Provisions are made in the bearing housing for the addition of a grease fitting which can be obtained elsewhere, or from the manufacturer by ordering kit Part No. 882159, which includes two (2) fittings.

90 DAYS

Re-grease the two (2) 1-3/8-inch bearings that support the impellor/fan shaft. Use Shell Alvania #3 grease or its equivalent. Impellor/fan shaft bearings should be lubricated.

Check to make sure that the set screws on the impellor/fan shaft bearings are tight.

Remove lint from around tumbler (basket), drive motors, and surrounding areas. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.

IMPORTANT: TO PREVENT DAMAGE, AVOID CLEANING OR TOUCHING IGNITOR and FLAME-PROBEASSEMBLY

Remove lint accumulation from inside control box and at the rear area behind control box.

42

Image 46
Contents MD-170 Installation/Operators Manual Maytag CoRetain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASGAS Supply or the Steam Supply Before ANY Covers or Specifications / Component Identification Specifications GAS and SteamSpecifications MDG-170 Gas MDS-170 Steam Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Round duct can now be connected to the dryer Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Create a Potential Fire HazardPage Page Page Page Page Electrical Information MDG-170 Gas MDS-170 Steam Page Page GAS Information Type of GAS Latest Edition Page Steam Information Steam Requirements High PressureSteam Damper System Diagram 621 kPaPage Switch Otherwise the Dryer will not Start Preparation for OPERATION/START-UPPreoperational Tests Natural Gas Inches W.C .5 millibars Shut Down Instructions Basket CoatingCompressed AIR Requirements 621 kPaService SERVICE/PARTS InformationParts Warranty Information Returning Warranty CardsCleaning Routine MaintenanceClean the lint drawer or screen every third or fourth load Createa Potentialfire Hazard Adjustments LubricationTroubleshooting Drive motor is not operating does not startBlower impellor/fan motor is not operating does not start Failed blower impellor/fan drive shaft bearingsFailed microprocessor controller computer Failed keyboard touchpad label assembly GAS Models Steam Models Dryer operates but is taking too long to dry Gas Models Condensation on main door glass Dryer or scraping noise at tumbler basket area AA. Excessive noise and/or vibrationFailed drive motor contactor relay Failed motor Failed blower impellor/fan drive shaft bearings Steam Models Gas Models Steam Models Condensation on main door glass Excessive noise and/or vibration Reversing Timer SPIN/DWELLADJUSTMENTS Timing LegendData Label Location / Information Data Label GAS Manifold Pressure for GAS DryersProcedure for Functional Check Replacement Components Microprocessor computer BoardModels manufactured with ADC module Part No Theory Of Operation P O R T a N T ADC P/N114501 02/16/00-25 2- 02/25/00-250