American Dryer Corp MD-170 manual Models manufactured with ADC module Part No

Page 68

e.Open main door. The dryer must stop and ALL output indicator lights on the back side of the micro- processor (computer) board must go out.

f.Try to restart the dryer with the main door open.

g.The microprocessor (computer) board's L.E.D. display must read "DOOR." h.Close the main door and restart the dryer.

i.Functional check of microprocessor (computer) board is complete.

2.Direct Spark Ignition (DSI) System

Models manufactured with ADC module Part No. 880815

a. Upon completing installation of the replacement Direct Spark Ignition (DSI) module, reestablish power to the dryer.

b. Start the drying cycle.

c. The ignition (DSI) module's L.E.D. indicator will light "red" for up to approximately 1.5 seconds (pre-purge time).

d. The module's indicator light will then turn "green." The gas valve will be energized and the ignitor probe will spark for approximately 8 seconds. The burner flame should now be established.

e. With the burner flame on, remove the flame sensor wire from the FS terminal of the DSI module.

f. The burner flame must shut off and the ignition module must lock out with the DSI module's indicator light "red".

g. Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h. The ignition module must proceed through the pre-purge, with the indicator light "red", the ignition trial time of approximately 8 seconds, with the indicator light "green", and then proceed to lock out with the indicator light "red".

i.Functional check of the Direct Spark Ignition (DSI) Module is complete.

1)Replace the flame sensor wire from the FS terminal to the DSI module.

64

Image 68
Contents MD-170 Installation/Operators Manual Maytag CoRetain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check of Replacement Section Important InformationSafety Precautions What to do if YOU Smell GASGAS Supply or the Steam Supply Before ANY Covers or Specifications / Component Identification Specifications GAS and SteamSpecifications MDG-170 Gas MDS-170 Steam Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Round duct can now be connected to the dryer Dryer Enclosure Requirements Fresh AIR Supply Exhaust Requirements Create a Potential Fire HazardPage Page Page Page Page Electrical Information MDG-170 Gas MDS-170 Steam Page Page GAS Information Type of GAS Latest Edition Page Steam Information Steam Requirements High PressureSteam Damper System Diagram 621 kPaPage Switch Otherwise the Dryer will not Start Preparation for OPERATION/START-UPPreoperational Tests Natural Gas Inches W.C .5 millibars Shut Down Instructions Basket CoatingCompressed AIR Requirements 621 kPaParts SERVICE/PARTS InformationService Warranty Information Returning Warranty CardsClean the lint drawer or screen every third or fourth load Routine MaintenanceCleaning Createa Potentialfire Hazard Adjustments LubricationTroubleshooting Drive motor is not operating does not startBlower impellor/fan motor is not operating does not start Failed blower impellor/fan drive shaft bearingsFailed microprocessor controller computer Failed keyboard touchpad label assembly GAS Models Steam Models Dryer operates but is taking too long to dry Gas Models Condensation on main door glass Dryer or scraping noise at tumbler basket area AA. Excessive noise and/or vibrationFailed drive motor contactor relay Failed motor Failed blower impellor/fan drive shaft bearings Steam Models Gas Models Steam Models Condensation on main door glass Excessive noise and/or vibration Reversing Timer SPIN/DWELLADJUSTMENTS Timing LegendData Label Location / Information Data Label GAS Manifold Pressure for GAS DryersProcedure for Functional Check Replacement Components Microprocessor computer BoardModels manufactured with ADC module Part No Theory Of Operation P O R T a N T ADC P/N114501 02/16/00-25 2- 02/25/00-250