3.Grounding
A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electric Code ANSI/NFPA NO.
For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a gas pipe or hot water pipe. The grounded cold water pipe must have metal to metal connection all the way to the electrical ground. If there are any
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.
4.Electrical Connections
NOTE: A wiring diagram is located in the front electrical control box for connection data.
a. Gas Models ONLY
NOTE: A CIRCUIT SERVING EACH DRYER MUST BE PROVIDED.
1)Single Phase (1ø) Wiring Connections/Hookup
The electrical connections on ALL
20